C850 532015 Rev. A
ENGLISH
11.5 PROGRAMMING
To program automated system operation, you must access “PROGRAMMING
mode.
Programming is divided into three levels: BASIC, ADVANCED and EXPERT.
Changes to the programming parameters become
immediately effective, while final storage occurs
only upon exiting programming and returning to the
automated system status display. If the equipment
is powered down before returning to the automated
system status display, all changes made will be lost.
It is possible to return to the status display at
any point during programming at any level by
simultaneously pressing “F” and “-”
11.5.1 BASIC PROGRAMMING LEVEL
BASIC PROGRAMMING LEVEL is accessed by pressing F:
when pressed (and held) the name of the first function is displayed.
releasing the key, the function value is displayed and can be modified
using the + and - keys.
when F is pressed again (and held) the name of the following function
is displayed, and so on.
once the last function is reached, pressing F will exit programming
mode and the display will go back to showing the inputs status.
Display Funzione Default
L2
LOOP 2:
When this function is enabled, the loop
connected to the Loop2 input will serve as a
SAFETY / CLOSE function, i.e. it will operate
as a SAFETY during closing and, once it
is uncovered, it will command the board to
CLOSE.
Y = loop2 active
no = loop2 not active
Warning: if the function does not activate, the
state of Loop2 will in any case be available
on one of the duly set outputs (see advanced
programming level).
no
H1
BOOST LOOP 1 FUNCTION:
Y = Active no = Disabled
This function lets you increase the sensitivity
level at the time of detection. When the vehicle
moves away from the loop, the sensitivity will
return to the selected level. This system makes
it possible to maintain the detection contact
even in case of very tall vehicles or during the
transit of a tractor with trailer.
no
H2
FUNZIONE BOOST LOOP 2:
Y = Active no = Disabled
See BOOST LOOP1 function.
no
S1
LOOP 1 SENSITIVITY
Regulates the sensitivity of the loop
01 = minimum
10 = maximum
05
S2
LOOP 2 SENSITIVITY
Regulates the sensitivity of the loop
01 = minimum
10 = maximum
05
St
AUTOMATED SYSTEM STATUS:
Exit programming,
store settings and return to automated system
status display.
00 Closed
01 Pre-ashing during opening
02 Opening
03 Open
04 Paused
05 Pre-ashing during closing
06 Closing
07 Stopped ready to close
08 Stopped ready to open
09 Stopped with closing safety devices and then opens
10 Opening safety devices tripped, then opens
Display of the automated system status Stis
extremely important for the installation/maintenance
technician in order to distinguish the logical processes
that the board carries out during movement.
If, for example, the automated system status is
CLOSED, the display MUST read
00. When the
OPEN command is received, the display will
change to
01, if pre-flashing is enabled, or directly
to
02 (the OPENING movement) to then display 03
once the OPEN gate position is reached.
BASIC PROGRAMMING LEVEL
Display Function Default
dF
PARAMETER LOADING:
00 Neutral condition
01 FAAC 1 Default loaded
LEAVE ON 00 IF YOU DO NOT WISH TO
CHANGE PROGRAMMING.
For a description of the parameter dF refer to
section 11.5.2.
00
bu
BUS ACCESSORIES MENU
no = BUS devices entering request
section 11.5.3.
no
LO
OPERATING LOGICS:
A Automatic
A1 Automatic 1
EP Semi-Automatic step-by-step
E Semi-Automatic
PE Photocell automatic
C Dead-man
CU Custom
E
PA
PAUSE TIME:
Is effective only if an automatic logic has been
selected. Adjustable from 0 to 59 sec. in
one-second steps.
Next, visualisation changes to minutes and
tenths of a second (separated by a decimal
point) and time is adjusted in 10-second steps
up to the maximum value of 4.1 minutes.
e.g.: if the display shows 2.5, the pause time
corresponds to 2 min. and 50 sec.
20
L1
LOOP 1:
When this function is enabled, the loop
connected to the Loop 1 input will serve as an
OPEN function.
Y = loop1 active
no = loop1 not active
Warning: if the function does not activate, the
state of Loop1 will in any case be available
on one of the duly set outputs (see advanced
programming level).
no
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC C850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC C850 in the language / languages: English as an attachment in your email.

The manual is 13,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info