13ENGLISH
WITH PROBE NTC 10K
Remove the jumper on 1 and connect the NTC probe in the room that needs to be temperature-controlled through air ducting 1.
3 control modes:
AIr DUCTInG CHArACTErIsTICs (TEorEmA PlUs)
The stove has 2 independent outlets for air ducting.
Air ducting 1 - 2 are enabled by factory default.
Features:
diameter of air ducting outlet: 2x80 mm
maximum recommended air ducting length 8 m
temperature controlled air ducting
Speed regulation can be set in 3 modes: OFF, AUTO, COMFORT
independent air ducting with option for enabling/disabling (ONOFF)
FACTory DEFAUlT oPErATIon In AIr DUCTInG moDE
Air ducting 1 and 2 are always in request by factory default (jumpers on 1 and 2 present), and follow the stove settings.
- No settings necessary.
oPErATIon In AIr DUCTInG wITH THErmosTAT or ProBE (oPTIonAl)
The stove is tted with two independent motors for air ducting. The connection of an external thermostat or temperature probe (NTC 10K)
in inputs 1 and 2, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove.
Suce it to connect the thermostat/temperature probe and set the desired temperature.
For information on air ducting settings see chapter:" Menu - Air ducting"
WITH AMBIENT THERMOSTAT OPTIONAL
Remove the jumper on 1 and connect the ambient thermostat in the room that needs to be temperature-controlled through air ducting 1.
3 control modes:
OPERATION IN AIR DUCTING WITH AMBIENT THERMOSTAT OPTIONAL
SET congured to OFF
(the temperature setting is not visible)
The air ducting motor will remain o unless the fumes temperature exceeds the
normal operating temperatures
SET congured to AUTO
(the temperature setting is not visible)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised (CLOSED CONTACT) the air ducting motor will follow the stove settings.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch OFF and switch on again when there is a new request.
SET congured to COMFORT
(the temperature setting is not visible)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised (CLOSED CONTACT) the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set on the thermostat is reached (OPEN CONTACT), the
ducting motor will switch o and switch on again when there is a new request.
SAMe OPerAting SettingS FOr Air ducting 2 MOtOr
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame TEOREMA plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame TEOREMA plus in the language / languages: English as an attachment in your email.

The manual is 8.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame TEOREMA plus

Extraflame TEOREMA plus User Manual - German - 40 pages

Extraflame TEOREMA plus User Manual - Dutch - 40 pages

Extraflame TEOREMA plus User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info