22 ENGLISH
OPERATION AND LOGIC
IGNITION
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition
phase. After ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to STARTING.
PREPARATION
During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to WORK.
WORK
During the work phase, the stove reaches the set power set; see following item.
SET POWER
Set the operating power from 1 to 5 (using keys 2 and 3).
Power 1 = minimum level - Power 5 = maximum level.
SET H2O
Set the boiler temperature from 65 to 80°C (using keys 4 and 5).
PUMP OPERATION
The pump activates water circulation when the t° of the water inside the stove reaches approx. 60°C. As the pump always functions above 60°,
it is recommended to keep a heating area open at all times to allow for uniform operation, preventing blocks due to overheating. Normally
this area is dened as the “safety zone”.
SET THERMOSTAT
It is possible to activate/deactivate front ventilation and check the room temperature by means of the room temperature probe (integrated
in the
product). (See the chapter "ventilation" on the following pages.)
BLOW
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it lowers the stove power level and increases the ue gas exhaust motor for a programmed period of time.
When the cleaning phase is nished, the stove will re-start automatically and continue the working phase, returning to the selected power
level.
MODULATION and HOFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. If the
temperature increases beyond the set point, it will automatically switch o indicating HOFF, and will automatically go back on when the
temperature drops below the set point.
SWITCHOFF
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the default
parameters.
REIGNITION
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satised.
DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION!
DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE
FILLING PHASE! IN THE EVENT OF CONTINUED FAILURE TO LIGHT, CONTACT AN AUTHORISED TECHNICIAN.
ALL COMPONENTS APPLIED TO THE BURN POT, SUPPLIED WITH THE APPLIANCE,
WHICH CAN BE SEEN IN THE DRAWING TO THE SIDE, MUST ALWAYS BE INSTALLED
DURING USE.
REMOVAL WILL COMPROMISE THE SAFETY OF THE PRODUCT AND RESULT IN
THE IMMEDIATE NULLIFICATION OF THE WARRANTY PERIOD.
IN THE EVENT OF WEAR OR DETERIORATION, ASK THE AFTERSALES SERVICE
TO REPLACE THE PARTS REPLACEMENT DOES NOT FALL WITHIN THE PRODUCT
WARRANTY AS THE PART IS SUBJECT TO WEAR
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame MARINA IDRO H11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame MARINA IDRO H11 in the language / languages: English as an attachment in your email.

The manual is 13.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame MARINA IDRO H11

Extraflame MARINA IDRO H11 User Manual - German - 40 pages

Extraflame MARINA IDRO H11 User Manual - Dutch - 40 pages

Extraflame MARINA IDRO H11 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info