811762
20
Zoom out
Zoom in
Previous page
1/36
Next page
20 ENGLISH
VENTILATION
This feature uses the PRO AIR SETUP which allows for the ventilation to be adjusted according to 4 levels: OFF, QUIET, REGULAR, BOOST.
OFF When you want to use natural convection heat only, without the aid of the fans, for maximum quietness
QUIET: Ventilation works to optimise acoustic comfort. The fans run at a reduced speed.
REGULAR: To obtain the best possible balance between performance and comfort. This is the factory setting.
BOOST: When you want to feed the set heat output of the appliance into the room as fast as possible.
To set: OK > VENTILATION >SET
EASY SETUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the EASY SETUP function, it is possible to dose the pellets by increasing or decreasing the preset values.
In the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value which
is 0
If you notice an excessive deposit on the burn pot, access the EASY SETUP program and lower the value by one unit to “- 1”; then wait until
the next day and if there is no improvement, decrease again, to a maximum of “- 3”. If, on the other hand, it is necessary to increase the pellet
dosage, switch the factory value from "0" to "+ 1, + 2, + 3" as required.
To set: OK > EASY SETUP
EXCESSIVE PELLET DEPOSIT IN BURN POT NORMAL OPERATION MINIMUM PELLET DEPOSIT IN BURN POT
-3 -2 -1 0 +1 +2 +3
THIRD DECREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
SECOND
DECREASE
RANGE IF
THE FIRST IS
INSUFFICIENT
FIRST DECREASE
RANGE (TEST FOR
1 DAY )
OPTIMAL FACTORY
VALUE
FIRST INCREASE
RANGE
SECOND
INCREASE RANGE
IF THE FIRST IS
INSUFFICIENT
THIRD INCREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
N.B.: IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT, PLEASE CONTACT YOUR LOCAL
SERVICE CENTRE.
MODES
This menu is used to set the operating logic of the machine for the power used.
Range: (MANUAL, AUTOMATIC, AUX)
By selecting MANUAL mode, the user can choose the heat output level delivered and the type of VENTILATION, according to his/her
preferences.
The stove will operate only according to the settings set by the user.
By selecting AUTOMATIC mode, the user can set the desired room temperature and the VENTILATION to be used. The stove will adjust itself
automatically to reach the set temperature without exceeding it.
This function improves the use of the generator in terms of consumption and thermal and acoustic comfort and it reduces the need
for cleaning and maintenance.
By selecting AUX mode, the user can choose the power level delivered and the type of VENTILATION.
The stove will adjust its operation based on the external thermostat TA.
With the contact closed, the stove operates according to the set settings; with the contact open, the stove switches to minimum modulation
(or it switches o if the STAND BY function is active).
To set: OK > MODE > SET
N.B.: The appliance is designed to work in safe conditions at all times.
In some cases, changing the ventilation level may have no noticeable eect on the setting.
ACOUSTIC COMFORT HEATING SPEED
OFF
QUIET
REGULAR
BOOST
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame KATIA 9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame KATIA 9 in the language / languages: English as an attachment in your email.

The manual is 9.61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame KATIA 9

Extraflame KATIA 9 User Manual - German - 36 pages

Extraflame KATIA 9 User Manual - Dutch - 36 pages

Extraflame KATIA 9 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info