643371
21
Zoom out
Zoom in
Previous page
1/36
Next page
ENGLISH
SCRAPERS:
Use the scrapers, moving upwards (for models with upper scrapers) or pulling and pushing them (for the inserts and models with front
scrapers).
Please note: scrapers are preferably used when the stove is cold; if used when the stove is hot, it is recommended to use special
gloves to protect against the heat as they can get very hot.
DAILY
CLEANING AND MAINTENANCE
ALWAYS FOLLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS!
Make sue the power cable is unplugged since the generator could be programmed to start.
That the generator is cold in its entirety.
The ashes are completely cold.
Ensure an eective exchange of air in the room during the cleaning of the product.
A poor cleaning is detrimental to the proper functioning and safety!
MAINTENANCE
For correct operation, the generator must undergo routine maintenance by a qualified technician at least once a year.
The routine checks and maintenance operations must always be performed by qualified trained technicians in accordance with the applicable
regulations in force and with the instructions provided in this use and maintenance manual.
EVERY YEAR MAKE THE EXHAUST FUMES, SMOKE DUCTS AND "T"FITTINGS, INCLUDING CAPS AND INSPECTION
DOORS BE CLEANED  IF ANY CURVES AND ANY HORIZONTAL SECTIONS!
THE CLEANING OF THE GENERATOR FREQUENCY IS APPROXIMATE! THEY DEPEND ON THE QUALITY OF THE PELLETS
USED AND THE FREQUENCY OF USE.
IT CAN HAPPEN THAT THESE OPERATIONS SHOULD BE PERFORMED MORE FREQUENTLY.
CLEANING AND MAINTENANCE BY THE USER
Routine cleaning operations, as specified in this use and maintenance manual, must be performed with the utmost care according to the
instructions, procedures and frequency intervals described in this use and maintenance manual
CLEANING THE SURFACES AND COVERING
Never use abrasive or chemically aggressive detergents for cleaning!
The surface cleaning must take place when both the generator and the coating are completely cold. For the maintenance of surfaces and
metal parts, simply use a damp cloth with water or mild soap and water.
Failure to observe the instructions may damage the surface of the generator and invalidate the warranty.
CLEANING THE CERAMIC GLASS
Never use abrasive or chemically aggressive detergents for cleaning!
The cleaning of the ceramic glass is allowed only when the latter is completely cold.
To clean the ceramic glazing, simply use a dry brush and some damp newspaper dabbed in the ash. If the glazing is very dirty, only use a
specic ceramic glazing detergent. Spray a modest amount onto a cloth and wipe the ceramic glazing.
Do not spray cleaner or any other liquid directly on the glass or on the gaskets.
Failure to observe the instructions may damage the surface of the ceramic glass and invalidate the warranty.
CLEANING THE TANK PELLETS
When the tank empties completely, unplug the power cord from the generator and remove residues (dust, chips, etc..) from the tank empty,
before lling it.
21
21


Need help? Post your question in this forum.

Forumrules
1

Forum

extraflame-giusy-plus

Reset search

  • Hallo Zusammen,

    ich habe einen Extraflame Guisy .
    Im Display wird eine Fehlermeldung "Luftmengensensor ho" angezeigt.
    wie kann ich das beheben??
    In der Bedienungsanleitung finde ich keine Einstellung dazu.
    Submitted on 18-10-2021 at 08:36

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Giusy Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Giusy Plus in the language / languages: English as an attachment in your email.

The manual is 6,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Giusy Plus

Extraflame Giusy Plus User Manual - German - 28 pages

Extraflame Giusy Plus User Manual - Dutch - 28 pages

Extraflame Giusy Plus User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info