CLEANING AND MAINTENANCE
ALWAYS FOLLOW THE INDICATIONS IN MAXIMUM SAFETY!
Make sure that the power supply cable plug is disconnected, since the generator could be programmed to switch-on.
That the generator is completely cold.
The ashes are cold.
Guarantee eective ventilation of the room when cleaning the product.
Lack of cleaning jeopardises correct operation and safety!
MAINTENANCE
For correct functioning, the generator must undergo routine maintenance by a qualied technician, at least once a year.
The periodic controls and maintenance must always be performed by specialised technicians, which operate in compliance with the
regulations in force and the indications given in this use and maintenance manual.
PERIODIC CLEANING BY THE USER
As indicated in this use and maintenance manual, periodic cleaning must be performed paying great attention, after having read the
indications, to the procedures and times described herein.
CLEANING THE SURFACES AND COVERING
Never use abrasive or chemically aggressive detergents for cleaning!
The surfaces must be cleaned when the generator and covering are completely cold. For maintenance of surfaces and metal parts, just use a
cloth dampened in water or water and neutral soap.
Failure to comply with the indications can damage the surfaces of the generator and cause the warranty to become null and void.
CLEANING THE CERAMIC GLASS
Never use abrasive or chemically aggressive detergents for cleaning!
The ceramic glass must only be cleaned when cold!
To clean the ceramic glass, just use a dry brush and newspaper dampened and passed through the ash. If the glass is very dirty, use a detergent
specic for ceramic glass exclusively. Spray a modest amount on a cloth and use it on the ceramic glass. Do not spray the detergent or any
other liquid directly onto the glass or gaskets!
Failure to comply with the indications can damage the surface of the ceramic glass and cause the warranty to become null and void.
CLEANING THE PELLET HOPPER
When the hopper is completely empty, disconnect the generator power supply cable and rst remove the residues (dust, shavings, etc.) from
the empty hopper before lling it.
EVERY YEAR HAVE THE FUMES EXHAUST PLANT, FUME DUCTS AND "T" FITTINGS AND INSPECTION CAPS CLEANED
 BENDS AND HORIZONTAL STRETCHES IF PRESENT!
THE CLEANING FREQUENCY OF THE GENERATOR IS INDICATIVE! IT DEPENDS ON THE QUALITY OF THE PELLETS
USED AND FREQUENCY OF USE.
THESE OPERATIONS MAY HAVE TO BE PERFORMED MORE FREQUENTLY.
EVERY DAY
SCRAPERS:
The heat exchangers must only be cleaned when cold! Its cleaning
guarantees constant heat output over time. This maintenance
must be performed at least once a day. To do this, use the scrapers
positioned in the upper part of the generator, making
upward and
downward moments several times.
THE FOLLOWING IMAGES ARE ILLUSTRATIONS ONLY.
TO FIND OUT WHICH IS YOUR NEAREST AFTER-SALES CENTRE, CONTACT YOUR DEALER OR VISIT THE WEBSITE
WWW.LANORDICA-EXTRAFLAME.COM
THE IMAGES ARE ILLUSTRATIONS ONLY.
28
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Fiandra Idro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Fiandra Idro in the language / languages: English as an attachment in your email.

The manual is 5,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Fiandra Idro

Extraflame Fiandra Idro User Manual - German - 36 pages

Extraflame Fiandra Idro User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info