27ENGLISH
AUX
If the producer's conveyed wave accessories are used, the connection must be made by the qualied technician directly in the board.
Contact the dealer for further details
LCD HANDHELD REMOTE ROOM PROBE CALIBRATION
This mode allows calibration of the room temperature detected by the LCD handheld remote (with ventilation active only). For correct
calibration, it is recommended to position the LCD handheld remote in a room with constant temperature and wait for at least two hours.
Below nd the calibration procedure:
Access the menu and reach TECH MENU”.
Set the access key "F4". - "ADJ REMOTE PROBE"
Use the
OK
or
OK
keys to adjust the desired room calibration.
Save and exit via the
OK
key.
ADDITIONAL THERMOSTAT
N.B. : Installation must be performed by an authorised technician
It is possible to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following the procedure
described in the next step (it is recommended to position the optional mechanical thermostat at a height of 1.50 m from the oor) . Stove
operation with external thermostat connected in the clamp TA can be dierent on the basis of activation or deactivation of the STAND
BYfunction.
By default, the clamp TA exits jumpered, therefore it always has closed contact (on request).
ADDITIONAL THERMOSTAT FUNCTIONING WITH STANDBY ACTIVE
When the function is activated, STBY will be shown on the display. When the contact or external thermostat is not satised (open contact
=temperature reached), the stove will switch o. As soon as the contact or external thermostat switches to the "not satised" status (closed
contact / temperature to be reached) it will re-ignite.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in HOFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT OPERATION WITH STANDBY DEACTIVATED
When the contact or external thermostat is satised (open contact / temperature reached), the stove will go to minimum. As soon as the contact
or external thermostat switches to the "not satised" status (closed contact / temperature to be reached) it will start to work again at the pre-set
power.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in HOFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL FUNCTIONS
ADDITIONAL THERMOSTAT INSTALLATION
Switch the appliance o using the master switch positioned on
the rear of the stove.
Remove the plug from the socket.
Connect the two cables of the thermostat to clamp (TA),
positioned on the rear of the machine.
DEPRESSURE NOTICE
It allows to activate the warning buzzer if the door or hopper is open.
Please note: activating this buzzer may reduce battery life by 30%.
Battery life depends on use.
To set: OK>SETTINGS>DEPRESSURE NOTICE
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Fiandra Idro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Fiandra Idro in the language / languages: English as an attachment in your email.

The manual is 5,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Fiandra Idro

Extraflame Fiandra Idro User Manual - German - 36 pages

Extraflame Fiandra Idro User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info