11 MG302-EU-EN V2.0 4/11
AUTORANGING/MANUAL RANGE SELECTION
When the meter is first turned on, it automatically enters the AUTO RANGE mode. This
automatically selects the best range for the measurements being made and is generally the best
mode for most measurements. For measurement situations requiring that a range be manually
selected, perform the following:
1. Press the RANGE key. The “AUTO” display indicator will turn off.
2. Press the RANGE key to step through the available ranges.
3. To exit the MANUAL RANGE mode, press EXIT
Note: MANUAL RANGE is not available for the Temperature functions.
MAX/MIN
1. Press the MAX/MIN key to activate the MAX/MIN recording mode. The display icon "MAX" will
appear. The meter’s left-most auxiliary display will show and hold the maximum reading,
updating only when a new “MAX” occurs. The display icon "MIN" will then appear. The right-
most auxiliary display will show and hold the minimum reading, updating only when a new
“MIN” occurs.
2. To exit MAX/MIN mode press EXIT.
RELATIVE MODE
The relative measurement mode displays readings that are relative to a stored reference value. A
reference voltage, current, etc. can be stored and measurements are made in comparison to that
value. The displayed value is the difference between the reference value and the measured value.
1. Perform the measurement as described in the operating instructions.
2. Press the REL button to store a reference reading; the "" indicator will appear on the display.
3. The auxiliary display on the right displays the initial reading (the stored value).
4. The auxiliary display on the left displays the actual currently measured value.
5. The main display shows the Relative value (measured value minus the stored value).
AC+DC
In the VAC, mV(AC), 10A(AC), mA(AC) and uA(AC) measurement modes, press the EXIT button
for 2 seconds to enter AC+DC test mode. The LCD shows the AC+DC icon. Press EXIT to exit this
mode.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extech MG302 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extech MG302 in the language / languages: English as an attachment in your email.

The manual is 0,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extech MG302

Extech MG302 User Manual - German - 19 pages

Extech MG302 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info