564722
6
Zoom out
Zoom in
Previous page
1/37
Next page
6


The machine must be connected to the electrical mains via a double-pole socket with an earthing contact,
wherein the allowed current is at least 16 A. A three-wire cable with copper wires having section at least 1.5 mm2 or
aluminium wires having section at least 2.5 mm2 must be supplied to the socket. The phase wire must be connec-
ted via an automatic device of electric mains protection intended for the maximal current (operating current) 16 A
having operation time not exceeding 0.1 s.
If the socket has not supply of the aforesaid cable or it is far from the place of machine installation, the electrical
mains and socket installation should be improved. Improvement of the electrical mains and socket installation must
be carried out by the qualified personnel.
IT IS PROHIBITED to provide earthing by means of an individual wire, as well as with the aid of the heating,
water supply or sewerage equipment.



3.4.1 The machine is to only be connected to the cold water supply network via a water supply cock having a
¾-inch threaded branch.
3.4.2 The following should be done before connection of the machine to the water line:
— the water line cock is to be opened and water is to be drained so that to wash out sand and rust from pipes;
— filter cleanness is to be checked in the filling hose in accordance with figure 5 and 6 and to the machine;
if the filling hose has a protecting system in accordance with figure 6, attention should be paid to the colour
in a special window of the hose. The yellow colour of the window shows the good state of the hose;
the filling hose is to be connected to the threaded branch of the water supply cock in accordance with figure
5 and 6 and to the machine in accordance with figure 7 by tightly screwing in nuts by hand.
3.4.3 During washing the water supply cock must fully be opened in accordance with figure 8.
3.4.4 In accordance with figure 9 the drain hose must be located at the height of at least 60 and not exceeding
90 cm from the floor level. If this rule is not observed, the machine will not work.
3.4.5 For water drainage directly to sewerage the drain hose of the machine is to be installed above the disc-
harge elbow (a siphon) to a sewage pipe having the internal diameter at least 40 mm so that to avoid back suction
of effluent water to the machine.
The drain hose may directly be connected to the siphon in accordance with figure 10, if the siphon has a branch
for its connection.
3.4.6 When water is drained to a basin or a bath the hose should be fixed in the place of bending by means of a
special bracket included to the supply in accordance with figure 11. The hose must not be immersed to water.


3.4.7 After connection of the machine to the water line and sewage tight connection of hoses should be checked
– places of connection must be dry.
 



OPEN
CLOSED
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Exquisit WA7214 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Exquisit WA7214 in the language / languages: English, German as an attachment in your email.

The manual is 3,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info