642850
40
Zoom out
Zoom in
Previous page
1/64
Next page
40
EN
a wooden floor, it is recommended to install the Machine in the corner of the room.
The Machine should be levelled precisely horizontally by screwing its adjustable supports in or out
(Fig. 7): loosen lock nuts 2 of the supports with a spanner, adjust the height of the supports, and tighten the
lock nuts. A wrong installation of the Machine by its horizontal level and low tightening of the lock nuts may
be in the future a source of vibration and excessive noise during its operation.
CONNECTING TO ELECTRIC MAIN
CAUTION! The Machine must be grounded.
The Machine should be connected to the electric main through the bipolar receptacle with a grounding
terminal. The current capacity of the receptacle should be not less than 16 A. Three-wire cable with a copper
wire strands having a cross-section at least 1,5 mm
2
(or with an aluminum strands having a cross-section at
least 2,5 mm
2
) should be connected to the receptacle.
Phase conductor must be hooked up through an automatic safety device of electric main power pro-
tection which is rated for maximal current (operating current) of 16 A. The device must have an actuation
time up to 0,1 s.
If receptacle has no terminated mentioned above cable or have a location remote from the Machine,
it is necessary to upgrade the electric main and install a new receptacle. Works on electric main upgrading
and receptacle installation must be carried out by skilled personnel.
IT IS FORBIDDEN to wire the connection to ground by a single wire, through the heating, water supply,
or sewerage facilities.
CAUTION! Manufacturer (or Seller) is not responsible for any damages of ownership and to health
arising from violation of above requirements to the hooking up procedure.
CONNECTING TO WATER CONDUIT AND SEWERAGE
The Machine should be connected to the cold water conduit only through the water delivery cock with
the help of rubber bench pipe of 3/4 inch.
Prior to connect the Machine to the water conduit, open the cock and let the water flow down thus
making washing down the contaminations of sand and rust out off the pipes.
The filling hose of Machine is equipped with AQUASTOP” protective system. Check up the filling hose
prior to connect the Machine. Keep an eye on following circumstances: In accordance with Fig. 8, a yellow-
orange color should be seen through the special window; if the color is red, than the hose is out of service.
Connect the filling hose to the threaded branch pipe of the water delivery cock in accordance with Fig. 8 and
to the solenoid-operated value in accordance with Fig. 9 having tightened the nuts by hand.
CAUTION! Do not sink the hose with a system “AQUASTOP” in water.
Water delivery cock should be fully opened during washing in accordance with Fig. 10.
The drain hose should be laid on the height of not less than 60 and not more than 90 cm against the
ground level in accordance with Fig. 11.
Violation of these requirements may cause Machine’s failure.
To drain water directly in sewerage, mount the Machines drain hose above the drain elbow pipe (siphon
drain) in the sewerage pipe having an inner diameter not less than 40 mm.
This prevents back siphonage of drainage water in the Machine.
If the siphon drain equipped with a branch pipe to connect the drain hose, it can be connected directly
to siphon drain in accordance with Fig. 12.
When the water drained in the kitchen sink or bath, the hose should be secured, in accordance with
Fig. 13, in the bend point by a special bracket included in delivery set.
Do not sink the hose in water.
CAUTION! Filling and drain hoses, after they have been connected to the water conduit and
Figure 8 Figure 9 Figure 10
CLOSED
OPEN
�lter
solenoid-operated valve
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Exquisit WA 6014 A plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Exquisit WA 6014 A plus in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info