814231
18
Zoom out
Zoom in
Previous page
1/28
Next page
Menu M6 LOAD INITIAL
This command is only available when the stove is OFF and allows the auger tube to be loaded the first time the stove is started when the pellet hopper is empty.
After selecting the INITIAL LOAD menu, “Press more” will scroll on the display. Then press P2 (increase). The exhaust blower switches on at the maximum speed
and the auger tube (auger tube LED on) starts working. They will switch off once the period of time indicated on the display has elapsed or after pressing the P3
button.
Menu M7 STATE STOVE
After entering menu M7 by pressing P3 button, the status of a number of parameters with stove in working mode scrolls on the display. The table below contains
an example of the scrolling values on the display including their meaning.
Displayed status Meaning
3.1” - Pellet loading auger status 52’ - Time out Toff - Thermostat status 106° - Flue gas temperature 1490 - Flue gas extraction speed
Menu M8 SET TECHNIC
This menu item is reserved for the stove installer. After entering the access key using buttons P1 (decrease) and P2 (increase), the various operating parameters
of the stove can be set.
Menu M9 ESCAPE
Selecting this item, pressing button P3 will exit the menu and return to the previous status.
08.3 USER FUNCTIONS
Standard operation of a control board correctly installed on a stove is described below with reference to the functions available to users.
TYPE OF SYSTEM, CHOICE OF OPERATION MODE (can only be set by a technician/installer)
Access the technical calibration menu and enter the SETTINGS FACTORY menu. Pr 20 established how the product is to be used:
MODE 1: THERMO-STOVE mode. The thermo-stove works according to the temperature of the water in the boiler. The heat output and temperature of
the water in the boiler can be set by the user. When the water temperature in the boiler is reached, the thermo-stove will go into modulation or stand-by
if, activated.
MODE 2: THERMO-STOVE mode + T.EXT. The thermo-stove works according to the temperature of the water in the boiler and the external thermostat.
When the external thermostat is not on call, the thermo-stove goes into modulation or stand-by, if activated.
MODE 3: STORAGE WATER HEATER mode. The thermo-stove works according to the temperature of the water in the boiler as a storage water heater.
Stove ignition
First connect the stove plug to the mains and load the pellet hopper.
Be careful not to empty the entire bag at once. Perform this operation slowly.
The combustion chamber and the burn pot must be cleaned, removing any combustion residue. Verify that the hopper lid and the door are closed. Failure to do so
could cause a malfunction of the stove and subsequent related alarms. Upon initial start-up ensure that in the burn pot there are no components that will burn (feet
bag, instructions, etc.).
Hold P3 button down for a few seconds to switch on the stove. The successful switching on procedure is indicated in the display with the message “START” and
the flashing ON/OFF LED.
During this phase, the stove goes into pre-heating status; both the glow plug (as indicated by the corresponding L5 glow plug LED) and the exhaust blower switch
on.
Any problem detected during the switching-on phase is indicated on the display and the stove goes into alarm status.
Pellet loading
After approx. 1 minute, the pellet loading phase begins, the display shows the message LOAD PELLET and the ON\OFF LED illuminates intermittently. During the
first stage, the auger tube feeds the pellets to the burn pot for a period of time (auger L5 LED on), the exhaust blower speed is set by an internal parameter and
the glow plug is still on (glow plug L5 on).
In the second phase, once the preset time has elapsed, the auger switches off (auger L5 LED off) for the preset time, while the exhaust blower speed and the glow
plug remain in the previous state.
In case of ignition failure at the end of this phase, the auger tube switches back on and stays on for the preset time, the exhaust blower speed is set by an internal
parameter and the glow plug stays on.
Fire present
Once the fume temperature has reached and exceeded the preset parameter, the stove goes into ignition mode: the message FLAME LIGHT appears on the
display and the ON/OFF LED begins to flash.
In this phase, the temperature remains stable for the preset time.
The exhaust blower speed is set by an internal parameter, the auger stays on for a certain period of time (auger L5 LED intermittent ) and the glow plug is switched
off (glow plug LED off).
Any problem during this phase will cause the control board to stop and the stove to go into error state.
Stove operational
Once the present fire phase is over, the stove switches to work mode which is the normal operating mode. The message (UORK) appears on the display and the
ON/OFF LED switches on. The heat output can be set by pressing the P2 button.
If the fume temperature reaches the threshold set by parameter Pr15, the air exchanger fan switches on. (exchanger LED lit).
IMPORTANT: During this phase, after a period of time set by the Pr03 parameter, the stove carries out burn pot cleaning. The message "CLEANING FIRE-
POT" scrolls on the display, the Auger tube is on (corresponding LED illuminated) at a speed set by the Pr09 parameter and the exhaust blower at a speed set by
PR08 parameter. Once the preset parameter time has elapsed, the stove returns to working status.
Changing the set heat output (MODE 1, MODE 2)
During normal operation of the stove (UORK), heat output can be changed by using the P2 button. (Set heat output LED on).
Press P2 button again to increase the heat output and P1 button to decrease it. The display will show the set heat output.
Do not press any button for 5 seconds or press P3 button to exit the setting mode. The heat output cannot be set in MODE 3.
The boiler temperature reaches the set temperature (SET boiler temperature)
When the boiler temperature is reached, the stove heat output is automatically set to the minimum value. During this phase, the display shows the message
“MODULATE”. If the temperature falls below the set value, the stove will go back to “UORK” mode and to the previously set heat output (Set heat output).
Stand-by
When enabled in the menu, the STAND-BY command allows the stove to be switched off after complying with the following conditions.
This is enabled if, for a time given by a preset parameter, the boiler temperature is higher than the set temperature plus a preset delta.
17
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor TEK 80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor TEK 80 in the language / languages: English as an attachment in your email.

The manual is 2.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor TEK 80

Eva Calor TEK 80 User Manual - German - 28 pages

Eva Calor TEK 80 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info