07.1 HYDRAULIC CONNECTION
CAUTION:
THE FOLLOWING ARE NOT PROVIDED WITH THE ITEM: AUTOMATIC BLOW VALVE, SAFETY VALVE, ELECTRONIC PRESSURE SENSOR, or EXPANSION
TANK.
Specifications of the pump to be installed: Electronic pump with a head of at least 6 metres.
Specifications of the Expansion tank to be installed according to the system:
For a correct sizing of the tank, the following operating parameters of the system are required:
C Volume of water in the system including boiler, pipes and heating elements with an overestimate of 15-20%. In principle, this is between 10 and 20 l for
every 1000 kcal/h (1.163 kW) of boiler heat output.
e Coefficient of expansion of water, corresponding to the maximum difference between the boiler thermostat calibration temperature and the water
temperature when the system is switched off. Examples of calculation displayed in the following table.
Coefficient e of expansion of water
TEMPERATURE
DIFFERENCE
COEFFICIENT e
0
0.00013
10
0.00027
20
0.00177
30
0.00435
40
0.01210
50
0.01450
55
0.01710
60
0.01980
65
0.02270
70
0.02580
75
0.02900
80
0.03240
85
0.03590
90
0.03960
100
0.04340
110
0.05150
Safety hydraulic circuit according to EN 1487:2014 or equivalent in force (STORAGE HEATER INSTALLATION MODE ONLY):
Safety units are devices used in sanitary installations for the protection of storage water heaters. They consist of a number of different components which perform
the following functions: - safety, to prevent the pressure of the fluid contained in the storage heater from reaching dangerous limits - anti-pollution, to prevent the
return of hot water to the cold water supply - shut-off, to isolate the supply and allow maintenance and control of the boiler circuit. They consist mainly of:
SHUT-OFF COCK
NON-RETURN VALVE
NON-RETURN VALVE CONTROL DEVICE
SAFETY VALVE
MANUAL DRAIN KNOB
HYDRAULIC LOAD SHUT-OFF DEVICE
P
ia Absolute preload pressure of expansion tank, the sum of the respective preloads of the
tank (determined by the system) and the atmospheric pressure:
Pia = Pir + Patm
Pfa Absolute pressure setting of the safety valve, obtained by adding the respective
pressure of the valve and the atmospheric pressure:
Pfa = Pfr + Patm
Given these parameters, the formula is as follows:
V, in litres, is the result of the calculation. For optimal sizing, the next largest tank that is
available on the market will need to be chosen
13
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor TEK 80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor TEK 80 in the language / languages: English as an attachment in your email.

The manual is 2.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor TEK 80

Eva Calor TEK 80 User Manual - German - 28 pages

Eva Calor TEK 80 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info