In compliance with the current installation regulations, the pellet heating stove should be installed in a ventilated place with air that is sufficient to ensure correct
combustion and therefore good operation. The room must have a volume no less than 20 m3 . In order to ensure good combustion (40m3/h of air) there must be a
"combustion air intake" that reaches an external wall or a wall of an adjacent room with an external air intake (Ø 80mm minimum diameter). The adjacent room
must not be a bedroom or bathroom, or contain any fire risks, such as storerooms, garages, combustible materials stores, etc. These air intakes must be made in
such a way as to avoid being blocked internally or externally, and should be covered with a grille, metal net or suitable protection, as long as the minimum diameter
is not reduced.
When it is operational, the pellet heating stove can cause a negative pressure in the room where it is installed. Therefore there should not be in the same room
other naked flame devices, with the exception only of type c stoves (watertight) unless they are fitted with their own air flow.
They must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or dust
that can cause greenhouse gas emissions or which can easily ignite with sparks. Before installing the pellet heating stove, it must be remembered that all finishes
or any beams made of combustible material must be positioned at a suitable distance and outside the irradiation area of the stove itself; furthermore, it must be
borne in mind that in order not to compromise the correct operation of the appliances, air must be allowed to circulate inside its housing to prevent overheating,
this is possible by respecting the minimum distances and making ventilation holes.
The use of hosing is recommended that connects the appliance to the hydraulic system as, in the case of ordinary or extraordinary maintenance, this makes it easy
to move. It is also recommended to install a dirt separator as the electronic pump could capture the dirt of the system and become jammed.
07.1 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance. Particular attention must be paid when
the stove is an integration to the system and all the equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230V while the frequency is 50 Hz.
The electrical system, at the connection point, must include an earth connection as required by the Regulations 73//23 EEC and 93/98 EEC.
07.2 EXTERNAL THERMOSTAT
In these heating stoves it is possible to install an external thermostat. This operation may only be performed by authorised personnel. Use a 2-pole cable with
everyday double insulation. In the event that the thermostat is closed, the stove functions at the power set. If the thermostat opened, the stove would work in
MODULATE mode until the thermostat closes.
08. ELECTRONICS WITH HYDRO STOVE 6-BUTTON LCD DISPLAY
08.1 CONSOLE
Figure 1 describes the meaning of the status indicators appearing on the display left side.
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available according to the access
level can be modified by entering the menu.
Depending on the operating mode, the displays can take on different meanings depending on the position on the display.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Sola at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Sola in the language / languages: English as an attachment in your email.
The manual is 4.77 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.