When refilling with wood it would be advisable to open the secondary air adjustment device (NOT THE PRIMARY ONE). Slightly open the door so that the stove
takes in oxygen, load the wood and close the firebox door. At the time of refilling there should be no lit fire in the chamber as, depending on the efficiency of the
fireplace, there may be a loss of fumes into the environment generated by the fire. Therefore, refilling is only recommended when thereare embers burning on the
fire bed.
CAUTION:
•Do not introduce into the stove an amount of fuel greater than that recommended in this manual.
•Don't smother the fire by closing the air vents.
•Do not leave the primary air adjustment device open (in the 8 kWand 12.5 kW stoves) during normal operation, thus avoiding overheating of the appliance
and subsequent deformation of it or the damaging of other parts such as the glass.
•Do not leave the firebox door open.
•Use proper protection equipment during refuelling: the firebox door handle and the adjustment devices might be very hot when the stove is operational.
•If the coals are extinguished, light them up with new wood shims to start the fire. If this does not occur, gases may form inthe combustion chamber and
subsequently, in extreme cases, an explosion may occur.
•Identify the correct ignition and the right amount of air (by adjusting the adjustment devices) to ensure that the stove works properly, based on the
characteristics of the fireplace and wood.
•The firebox chamber is made of a material called vermiculite. Although it is resistant, it is advisable not to throw wood onto it during refilling. Breakage
due to user incorrect behaviour in loading wood is not covered by the warranty.
•Over time, however, it is possible that small cracks may form in the vermiculite. This is absolutely normal and in no way affects the correct functioning of
the stove.
.
09. CLEANING AND ROUTINE MAINTENANCE
The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation.
The Purchaser must regularly clean the stove, following the instructions contained in this Instruction Manual. Failure to clean and/or to perform ordinary maintenance
of the stove can cause: operating anomalies, clogging of thepipes, inefficient or slow combustion, overheating of the stove and catching fire of the same.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused
by the failure/incorrect cleaning and routine maintenance of the stove.
Perform daily cleaning in a completely cold stove as follows:
•Empty the ash drawer, vacuuming it or by throwing the ash into the domestic waste;
•Vacuum the combustion chamber, ensuring that there are no burning embers remaining. If embers are still burning, the vacuum cleaner will catch fire;
•Remove the ash that collects inside the firebox and on the door.
•Clean the glass with a damp cloth or with a ball of damp newspaper dippedin ash. If the operation is performed with the stove hot there is a risk of the
glass exploding.
Caution: Only use a dry cloth to clean the stove. Do not use abrasive material or products that could corrode or bleach surfaces.
10. NON-ROUTINE CLEANING AND MAINTENANCE
The Buyer must have the flue and flue pipe cleaned annually, before winter, by qualified technical personnel and retaining the documentation to be shown in the
event of activation of the warranty.
Cleaning must also be carried out before resuming use of the stove, as during the summer there may have been impediments to the regular flow of exhaust gases
(e.g. nesting, fouling or obstruction).
The lack of extraordinary maintenance can cause: depression with poor draught and a slow flame, clogging of the fire pit and pipes, overheating of the stove and
fire in the smoke pipe.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the
failure/incorrect extraordinary maintenance of the stove.
It is not uncommon, at the first cold spell and with wind for fires to ignite in the chimney due to the residue build up; some advice in the unfortunate event of this
happening is:
•Block air supply to thepipe immediately;
•Use large handfuls of sand or salt, not water, to extinguish the fire;
•Move objects and furniture away from the hot chimney.
Caution: Only use a dry cloth for cleaning the outside of the stove. Do not use abrasive material or products that could corrode or bleach surfaces.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Margherita at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Margherita in the language / languages: English as an attachment in your email.
The manual is 2.3 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.