668834
27
Zoom out
Zoom in
Previous page
1/55
Next page
Second phase. Ignition
After the preparation phase, the display will show the message "LOAD PELLETS" and ignition
will begin. This second phase is divided in two parts: pre-loading and actual ignition. First, the pellet
feed screw is activated (the Feed screw ON LED lights up) for a variable time interval,
depending on the model, and pellets begin to fall inside the brazier. (Remember that the brazier
must be perfectly clean at this beginning of this stage). Once this "pre-loading" phase is
completed, the pellet feed screw will stop for a variable amount of time depending on the model
(from two to three minutes). After this waiting phase, the pellet feed screw will start to switch on at
regular intervals and pellets will then continue falling inside the stove brazier, while the glow plug
and then fume exhaust fan will both remain activated.
As soon as the pellets cover the glow plug hole, you will notice first a reddening and then the
onset of a small flame in the brazier.
If pellets continue to fill the brazier without this happening, manually stop the ignition process
without waiting for the stove to set off an alarm: "AL 5 NO START".
This second phase is completed when the stove detects successful triggering of the combustion
process, or rather after 4-5 minutes from the triggering of the first flame.
If combustion is not detected within a given amount of time, the no start-up alarm will be activated
("AL 5 NO START" message).
Third phase. Stabilisation
Once combustion triggering has been detected, the third phase will start and the display will show
the message "FIRE PRESENT". Pellet feeding is reduced and ventilation increased in order to
allow a stabilisation of the flame and disposal of excess pellets accumulated in the brazier during
the ignition phase. This phase lasts about 5 minutes.
Once the stabilisation phase has been completed ("FIRE PRESENT"), the stove passes to the
normal working phase.
6.3.2 No start-up
As said, if the onset of combustion is not detected, the no start-up alarm will be set off. The display
will show the message "AL 5 NO START" and an acoustic signal will be heard at regular intervals
(if the buzzer function is active in Menu 6).
To disable the alarm, hold and press the ON-OFF (4) (about 2 secondi) . The acoustic alarm
will stop and the stove will return to "FINAL CLEANING" status and then to "OFF."
Before starting another ignition cycle:
- Verify the cause of the alarm.
In particular:
Verify that the pellet tank is not empty.
Verify that the brazier is in the right position.
Remove the unburned pellets from the brazier (VERY IMPORTANT).
If the device does not ignite regularly, the main cause may be insufficient maintenance or poor
pellet quality.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro Slim 16 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro Slim 16 kW in the language / languages: English as an attachment in your email.

The manual is 5,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info