6.2 First ignition
Before igniting the stove, you MUST have a qualified technician perform "FIRST START-UP" and
calibration. For this purpose, we advise you to contact personnel part of our network of authorised
service centres. The company assumes no responsibility for malfunctions due to improper
installation, failure to install, incorrect first ignition, or improper use.
Make sure that electrical and plumbing connections have been performed properly. Also check
that the hydraulic system (on heating stoves and boilers) has a sufficient expansion tank for
maximum safety. Please note that expansion is calculated considering 6% of the whole volume
contained in the system. Any damage to the system or to equipment will not be considered under
warranty. The presence of the tank fitted on the unit does not guarantee adequate protection
against sustained thermal expansion of the system water.
Fill up the system through a refill valve (to be provided externally to the stove). During recovery,
it is advisable not to exceed a maximum pressure of 1 bar. Pressure can be read directly on the
pressure gauge (item 7 par. 5.5).
The water loading phase should be simultaneous to air exhaust.
Before lighting the stove, also check that the brazier is pushed back towards the rear wall
of the combustion chamber.
The first few times you light the stove, it may give off odours due to the evaporation of paint or
grease. Simply ventilate the room to make the odour go away, avoiding prolonged exposure as
vapours can be harmful to people or animals. Do not allow children to stay in the room during this
first phase.
When the tank is loaded for the first time, the feed screw must fill up for a given period. During this
time, pellets will not be distributed within the combustion chamber. To overcome this difficulty, use
the command "initial load" in menu 7 of the control panel (see further details to follow).
6.3 Ignition and normal operation
Before igniting the stove:
- Check that the furnace door is locked.
- Make sure that the pellet tank is full or contains such enough so that the stove will function for
the desired amount of time.
- Make sure that the brazier is clean, free of ashes, combustion residue or unburned pellets (if
necessary, remove the brazier and thoroughly clean it, then replace it with care in its
housing). In the event or start-up with the programmable thermostat, make sure that the
brazier is in the indicated conditions after last use.
When the stove is connected to the electrical system but not in work mode, the display will show
the message "OFF".
6.3.1 Stove start-up
To start up the stove, hold and press the start button (4) for 2 seconds
If you start the stove during the final cleaning phase, the display may show the message "WAIT
COOLING." In this case, wait for a minute before retrying ignition.
First phase. Preparation
The message "START" will appear on the display. In this phase, which lasts for about one minute,
the pellet glow plug activates and combustion chamber forced ventilation starts along with
activation of the fume extraction fan.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Hydro Slim 16 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Hydro Slim 16 kW in the language / languages: English as an attachment in your email.

The manual is 5,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info