B - Overload warning light
The overload warning light will light up if, an overload caused by the attached equipment is
detected, the inverter control overheats, or the AC voltage rises. The circuit breaker will
then kick in and stop the process of electricity generation in order to protect the generator
and connected equipment. The green AC alternating current warning light will go off and the
red overload warning light will light up. After a few seconds the engine will stop.
If the overload warning light lights up (and the engine has possibly already stopped) you
must do the following:
a) Switch all connected equipment off
b) Switch the engine off if it has not automatically been switched off
c) Reduce the total wattage of connected equipment to the maximum allowed load
d) Check that no ventilation openings are blocked and where necessary unblock them.
e) Once everything has been checked you can restart the engine
Warning!
The AC direct current supply is automatically reset when the engine is switched off and
restarted.
The overload warning light can light up for a few seconds if an electrical device is being
used that requires a high peak current when staring up, like a compressor or a
submersible pump. This is not a malfunction.
C DC Direct current application
N.B. Only for charging 12V batteries.
Instructions for charging a battery:
i) Set the Economy switch to the OFF position
j) Set the DC direct current overload protection (red
button) to OFF.
k) Prepare the battery for charging:
Uncouple the battery leads.
Remove the filler caps completely.
Fill with distilled water to the maximum level (if
necessary).
Measure the specific gravity of the battery fluid
with an acidimeter and calculate the charge
time according to the table on the right.
The specific gravity of the fully charged bttey
must be 1.26 to 1.28. It is recommended that
you carry out the above every hour.
l) Using battery leads connect the battery terminals to
the corresponding terminals in the DC direct
current socket on the generator: + on +, - on - !
m) Check that all leads are correctly connected and
switch the DC direct current overload protection to
ON.
IV-3 Stopping the engine
w) Switch all connected equipment off and disconnect all connections to the generator.
x) Switch the engine switch to the STOP position.
y) Close the fuel cock (OFF).
z) Close the ventilator knob on the tank cap (clockwise).
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eurom Independ-2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eurom Independ-2500 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info