820911
3
Zoom out
Zoom in
Previous page
1/3
Next page
3 / 3
7 • SETTINGS AND FUNCTIONS VIA REMOTE CONTROL
REMOTE CONTROL MDi/PDi (item no. EM10425509)
NB: For optimum reception, when programming the settings, point the remote control at the detector.
Please note that if the sun shines directly on the sensor, the standard detection range of approx. 8 m may be
dramatically reduced owing to the sun’s infrared rays.
1. Setting via remote control
The DIP switch 1 on the detector needs to be set as shown in the illustration.
Button Customised setting
Entering programming mode
Blue LED lights up on the detector, indicating “blue mode”
(programming mode). The connected lighting turns on.
Whilst in programming mode, the detectors movement sensor is disabled.
Set switch-on light value with button or fixed light value.
Inputting the current ambient lighting level (between 5 - 2000 lux)
as the switch-on value
Connected lighting and the blue LED switch off. Once the input process has been
successfully completed, the lighting turns on and the blue LED lights up continuously.
Fixed switch-on values (10 - 2000 lux)
Confirmed by blue and red LED on the detector flashing alternately.
Determining a time setting for channellighting-C1”: 1 min and 15 min (*) or
short pulse: once the detector has been triggered by movement (lighting is below
preset ambient lighting level), the lighting and the red LED will be switched on for
1 second and then off for 9 seconds.
Confirmed by blue and red LED on the detector flashing alternately.
Note * : 2 x key = switch-off delay time 30 min.
Valid for products marked with * on page 1.
Determining a time setting for channel “HVAC-C2”: 1 min and 60 min or
short pulse: once the detector has been triggered by movement, the channel
and the green LED will be switched on for 5 seconds and then off for 5 seconds.
Confirmed by blue and green LED on the detector flashing alternately.
Alternating between “fully automatic” andsemi-automatic” operation modes
Semi-automatic mode = press button, the blue LED will turn off for approx. 3 seconds.
Fully automatic mode = press button, the blue LED will flash for approx. 3 seconds.
Switching LEDs on / off (red / green LED)
To switch LEDs off = press button, the blue LED will turn off for approx. 3 seconds.
To switch LEDs on = press button, the blue LED will flash for approx. 3 seconds.
Reinstating factory settings
Confirmed by blue and red LED on the detector flashing alternately.
Exiting programming mode
Blue LED goes out; settings are now saved.
The detector will now operate automatically according to the preset values.
NB: If the programming mode is not exited by pressing the button, the detector
automatically exits the programming mode 10 minutes after the last button was pressed.
Additional functions via REMOTE CONTROL MDi/PDi remote control
Checking the range / detection using test mode
Connected lighting turns on – for clear inspection / pacing out of a detector’s field
of detection. Real-time, load-free indication of movement given by 2 flashes of the
blue LED.
NB: Exit test mode by pressing the “TEST” or “RESET” button.
Switch “lighting C1” on / off manually (replaces button)
“Continuous lighting 4 h ON / OFF” for “lighting-C1”
The lighting can be switched on or off at any time for a duration of
4 hours by pressing the button. Once the 4 hours have expired,
the detector switches back to the corresponding set operating mode.
NB: When the “4 h ON / OFF” feature is activated, the detector no longer responds to
movement and is not controlled by the light value.
Interrupting the “TEST”, “light ON / OFF”, “light 4 h ON / OFF” functions
The detector switches back to the corresponding set operating mode.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Esylux MD-C serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Esylux MD-C serie in the language / languages: English as an attachment in your email.

The manual is 0.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Esylux MD-C serie

Esylux MD-C serie User Manual - German - 3 pages

Esylux MD-C serie User Manual - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info