IP2163EN - 2014-08-05
9. Star t-up
WARNING The operations related to point 5 are performed without safety devices.
The display parameters can only be adjusted when the automation is
idle.
The automation automatically slows when approaching the end stops or
stop limit switches.
At every start-up the control panel receives a RESET and the first opera-
tion is performed at reduced speed (automation position acquisition).
1- Make a jumper for NC safety contacts.
2- Adjust the opening and closing stop limit switches, if any.
NB: The limit switches must remain pressed until the operation is completed and placed as
shown in the Ditec NEOS installation manual.
3- Set the desired opening direction from the
menu.
4- Manually move the sliding gate and make sure the entire stroke slides evenly and without
friction.
5- Switch on and check the automation is operating correctly with the subsequent opening and
closing commands (see paragraph 7.2).
Check that the limit switches are activated if used.
6- Connect the safety devices and (removing the relative jumpers) and check
they are working correctly.
7- To modify the operation and deceleration speed settings, automatic closing times and thrust
on obstacles, consult the menus.
8- Connect any other accessories and check they are functioning.
WARNING: Ensure that the forces exerted by the door wings are compliant with EN12453-EN12445
regulations.
9- If required, store the remote controls using command .
10- Once the start-up and check procedures are completed, close the container.
i
NB: in the event of servicing or if the control panel is to be replaced, repeat the start-up
procedure.
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec CS12M - IP2163 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec CS12M - IP2163 in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec CS12M - IP2163

Entrematic Ditec CS12M - IP2163 User Manual - German - 56 pages

Entrematic Ditec CS12M - IP2163 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info