609375
44
Zoom out
Zoom in
Previous page
1/56
Next page
102
IP2163EN - 2014-08-05
Type of
alarm
Display Description Operation LED
Power supply
operations alarm
R3 - Storage module not detected
(with RDX inserted) .
Insert a working storage module or
remove RDX.
R5 - Storage module not working (re-
gardless of RDX)
Replace the storage module.
Accessories alarm
A0 - Failure of test of safety sensor
on contact 6.
Check that device SOFA1-A2/GOPAV
is working correctly.
If the supplementary card is not in-
serted, check that
is not set to
/
A3 - Failure of test of safety sensor
on contact 8.
Check that device SOFA1-A2/GOPAV
is working correctly.
If the supplementary card is not in-
serted, check that
is not set to
/
A7 - Incorrect connection of contact
9 to G3
Check that terminal 1 and 9 are cor-
rectly connected.
A9 - Flashing light output short cir-
cuit alarm
Check that the flashing light is working
properly.
AB - Gate open indicator light
shortcircuit alarm
Check that the gate open indicator
light is working correctly.
Battery
B0 - Battery almost flat Check battery voltage.
Replace battery.
Power supply
alarm
P0 - No mains voltage. Check the control panel is powered
correctly.
Check the line fuse.
Check the mains power supply.
P1 - Microswitch voltage too low Check the control panel is powered
correctly.
Control panel
internal alarm
I2 - No communication between
parallel automations.
Check G1 (MASTER) - G3 (SLAVE)
and G3 (MASTER) - G1 (SLAVE) con-
nections.
Reset.
If the problem persists, contact
Technical Support.
I7 - Internal parameter outside lim-
its error
Reset.
If the problem persists, replace the
control panel.
I8 - Program sequence error Reset.
If the problem persists, replace the
control panel.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec CS12M - IP2163 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec CS12M - IP2163 in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec CS12M - IP2163

Entrematic Ditec CS12M - IP2163 User Manual - German - 56 pages

Entrematic Ditec CS12M - IP2163 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info