Line Selection:
proper programming and “call transfer” feature
code (available from the user manual of the wired
PBX system) in order to perform this function
correctly.
The following example is the instruction to route a
call back to the brand N’s PBX system by
pressing “Flash-7-0-1-8-3-0,” where a Flash key is
pressed followed by the call transfer code”70”,
then enter the extension number “1830”
immediately. Confirm the set up by press “SAVE”
using the left soft key.
1. Press MENU – 5 – 8 while the phone is in standby to enter
Line Select menu.
2. Use Up/Down arrow to switch between On and Off, default =
Off.
3. If set to On, when pressing TALK or entering a phone
number followed by pressing TALK key, the handset LCD
display will show “Select Line” followed by available lines (1-
4). Select from one of the available lines i.e. press “1” to
select line 1 and press “2” to select line 2.
Notes:
1. Only administrator can change AA settings.
2. Because AA setting is stored on the base station, the handset
must be in range with the base to make changes.
3. The maximum recording time for the greeting message is 128
seconds.
4. Allowing each line’s AA to be turned on or off separately is
useful if different lines are used for different purposes.
5. When AA is disabled, the line can be dedicated to either an
individual Handset ID or a Group ID.
6. The operator can be any individual handset or a group; it
doesn’t need to be an administrator handset (Handsets 10 and
11).
7. The minimum number of rings before the AA picks up cannot
be lower than two for the purpose of receiving the Caller ID
message.
4. This feature is also supported when selecting a second line
during call conferencing.
Change System Settings by Administrator
1. In addition to AA settings, there are two system parameters
that can be changed by the administrator: clear (de-register)
handset ID and set the next handset ID to be assigned by the
base.
2. From an administrator handset (Handset 10 or 11), press
Menu (Right) soft key.
3. Press number “9”, this will enter administration menu.
4. Press number “2”, handset enters System setting menu.
Line Dedication:
a. Clear Handset ID:
Press “1” and enter a two-digit Handset ID when prompted
to clear this ID for later assignment.
a. By default all incoming calls will ring all handsets.
b. To dedicate a handset to a specific line you must use an
administrative handset (ID 10 or 11).
b. Set next Handset ID to be assigned:
Press “2” and enter a two-digit Handset ID when prompted.
This is the ID that will be given out by the base to the next
handset registering with the base.
c. With the administrative handset, press Menu-9-1-4 for
Auto Attendant On and OFF. It will first show Line 1
ON/OFF. If you wish to dedicate line 1 to a specific
handset you need to select “Off”. This will turn off auto
attendant (automatic call distribution) for line 1. To
dedicate lines 2-4 use ¿orÀ scrolling key on the keypad.
c. Dial tone:
Press “3” to set up the dial tone to be either “Tone” or
“Pulse.” Press “1” to choose “Tone” or press “2” to choose
“Pulse.”
d. When asked, “Dedicate line?” choose “Yes”.
d. Flash time:
e. Enter handset ID number when asked for Extension
Number?
43
44
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Engenius Durafon 4X - SP922 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Engenius Durafon 4X - SP922 in the language / languages: English as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info