691901
9
Zoom out
Zoom in
Previous page
1/16
Next page
EmpirBus Connect-50 User manual Ver. 1.33 8/14
6.1.6!Analog!input!–!multi!switch!
The circuit below enables four separate momentary switches to be connected to a single input
channel. Connect the circuit to “Sensor GND” pin 32 and the desired channel. Note: Multi switch
channel setting is only possible for momentary switches. Only one button can be pressed at a time.
6.1.7!Frequency!input!-!digital!
Channel 6 and 22 could be configured to frequency input. Input signal is flank triggered at positive
flank with configurable thresholds level.
!
6.1.8!Signal!drive!-!output!
Input channel can be configured to drive up to 50mA plus or minus. This will be supplied via an
internal resistance, see below table for voltage drop.
Load
Voltage drop internal (+/- 20%)
10mA
1,3V
20mA
2,0V
30mA
2,7V
40mA
3,4V
50mA
4,0V
Thresholds level
Flank trigger
0
5
10
15
20
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EmpirBus Connect-50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EmpirBus Connect-50 in the language / languages: English as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info