667120
19
Zoom out
Zoom in
Previous page
1/40
Next page
19
GBGB
6. INSTALLATION OF THE INTERNAL UNIT
6.7 Positioning of pipes and cables
The electrical cable and condensate drain hose must be secured with the
coolant tube using the protective tape.

1 Aluminised tape
2 Refrigeration piping
3 Indoor unit condensation drain
4 Electrical connection cable
between the units
-
Provide to use a protection sheet for the cables exposed to the outside.
- It is recommended to set the cables with a drip-proof run in order to
avoid possible infiltrations of water in the outdoor unit.
- Combine the electrical connection cable of the two units to the refrige-
ration piping and wrap with reinforced tape, possibly alluminized .
- If the cable cannot be solid with the piping, make a suitable wall ancho-
rage by means of a cable fastener or hose clips..
6.8 Connections single unit
Apply the ferrite core to the connecting cable between the indoor and
outdoor unit (near the terminal block of the outdoor unit)
1(L)
L
S
N
W
2(N)
Internal Unit
Nucleus of ferrite
1(L)
S
W
2(N)
Outdoor unit
Power supply
Signal
N
L
Stand By
- Loosen the screws and insert the ends of the cable completely into the
terminal block, after this tighten the screws.
All'unità esterna
Unità interna
70 mm
10 mm
10 mm
50 mm
Fig. G
- Pull the cable lightly to make sure that the cables have been insert and
fixed rightly.
- After cables connection never forget to tight them to the cable gland.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Emmeti X-EVO - XX17W43 Wall indoor unit at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Emmeti X-EVO - XX17W43 Wall indoor unit in the language / languages: English as an attachment in your email.

The manual is 7,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Emmeti X-EVO - XX17W43 Wall indoor unit

Emmeti X-EVO - XX17W43 Wall indoor unit User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info