When in any of the above modes, press the MIN/MAX key to toggle
between the maximum or minimum values of those records and their
respective time and dates will also be shown.
For the wind and pressure minimum and maximum readings, the
same would apply except that the WIND or PRESSURE keys would
be used instead of the DISPLAY KEY.
Exiting the MIN/MAX modes
If the maximum and minimum modes with times and dates are dis-
played, press the PLUS(+) key twice to return the normal display
mode.
Resetting the MIN/MAX records
Whilst in the minimum or maximum mode, the time and dates are also
displayed along with the recorded values. If the MINUS(-) key is
pressed whilst any of these values are displayed, that particular
minimum or maximum record will be reset to current reading together
with the current time and date with the exception of the following:
The first case is Rainfall Total, which has neither maximum nor
minimum records since it will show only the total rainfall. Pressing
the MINUS(-) key, will reset the rainfall total value to zero and the
time recording to current time.
The second case is Rainfall 24h or 1h, which records maximum
rain count only for these respective times. Pressing the MINUS(-)
key in either of these two modes will reset the rain count to the
current rain count and time and date.
15. Alarm Programming Modes
Alarm Modes
As well as the normal time alarm, this feature will allow users to set a
range of specific alarms to meet specific weather and temperature
conditions set by the user. The weather station allows for the follow-
ing 13 alarms modes to be set:
1. Time alarm
2. Indoor temperature high alarm and low alarm
3. Outdoor temperature high alarm and low alarm
4. Indoor humidity high alarm and low alarm
5. Outdoor humidity high alarm and low alarm
6. Wind chill high alarm and low alarm
7. Dew point alarm high alarm and low alarm
8. Rainfall 24h alarm
9. Rainfall 1h alarm
10. Pressure high alarm and low alarm
11. Wind speed high alarm and low alarm
12. Wind direction alarm
13. Storm warning alarm
Setting Alarms:
For alarm setting, press the ALARM key once whilst in normal opera-
tion mode to enter the normal alarm time and by further pressing the
ALARM key will toggle through each of the alarm modes:
Note:
The alarm icon will automatically appear upon pressing the SET
key to tell the user the alarm is activated. Further pressing the
SET key will deactivate/reactivate the alarm.
Time alarm setting
1) Press the ALARM key to enter the normal time alarm
2) Press and hold the SET key to enter the alarm hour time set
mode (the hour digits will flash) and set the desired hour by using
the PLUS(+) or MINUS(-) keys
3) Press the SET key to enter the alarm minute time set mode (the
minutes digits will flash) and set the desired minutes using the
PLUS(+) or MINUS(-) keys
4) Press ALARM key to confirm followed by the MIN/MAX key to
return to the normal display mode.
Indoor temperature high alarm and low alarm setting
1) Press the ALARM key to enter the normal time alarm
2) Press the ALARM key again to enter indoor temperature high
alarm set mode
3) Press and hold the SET key to enter the indoor temperature high
setting values (digits will start flashing) and set the desired indoor
temperature high by using the PLUS(+) or MINUS (-) keys
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ELV WS2300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ELV WS2300 in the language / languages: English as an attachment in your email.

The manual is 0,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info