536725
17
Zoom out
Zoom in
Previous page
1/34
Next page
-15--50-
On/Off Selection DIP1 of SW2 DIP2 of SW2 Trigger reaction of LED
ON Walk Test mode High Sensitivity LED will be on once.
It implies high
sensitivity.
Low Sensitivity LED will flash twice.
It implies low
sensitivity.
OFF Normal mode High/Low LED does not light up.
Sensitivity
3. The setting of the DIP1 & DIP2 of SW2 can be distinguished from the LED
indication as follows:
In summary, the setting of DIP1 & DIP2 of SW2 is concluded as below:
4. Connect the 1/2 3.6V Lithium battery to the battery spring.
Note: When the battery is connected, the LED behind the lens will flash for 2-
3 minutes as warming-up duration until the PIR has stabilized when the LED
will then stop flashing and turn OFF.
5. In normal mode, remove the rear cover of the PIR detector. The Detector’s
LED will illuminate and the Control Panel should beep. It is because the
tamper switch fitted on the Detector has been activated.
6. When the Detector is fully installed i.e. battery cover is refitted; the Detector
will not detect movement for approximately 2 minutes after each activation.
(This feature is present to conserve battery power and maximize the battery
life).
7. In order to communicate with the Control Panel, the ID code of the Detector
needs to be learned by the Control Panel. By pressing the tamper switch
located adjacent to the PCB on the Detector will emit the ID code to the
Control Panel instantly, subject to the Control Panel being set at the Zone
setup mode.
TESTING THE PIR DETECTORS
Ensure that the system is in Test Mode.
With the PIR detector set in Test mode and mounted in position on the wall,
allow 2-3 minutes for the detector to stabilize before commencing the Walk Test.
SW2 DIP1 DIP2
ON Walk Test Mode High sensitivity
OFF Normal Mode Low sensitivity
EXIT DELAY
Scroll through the menu until ‘6-1 Exit Delay’ is displayed. The current setting
will also be displayed.
Default setting: ON
To change the setting press .
Press to enable the Exit delay and enter the required exit delay period
(1-250s), or
Press to disable the Exit delay.
Press to return to top level Partial Arm 1 Setup menu.
ENTRY DELAY BEEP
This controls the warning beep which operates during the Entry Delay period
when Partial Arm 1 is active.
Default setting: ON
Scroll through the menu until ‘6-2 Entry Delay Beep’ is displayed. The current
setting will also be displayed.
To change the setting press .
Press to enable the Entry-delay beep, or
Press to disable the Entry-delay beep.
EXIT DELAY BEEP
This controls the warning beep which operates during the Exit Delay period when
Partial Arm 1 is initiated.
Default setting: ON
Scroll through the menu until ‘6-3 Exit Delay Beep’ is displayed. The current
setting will also be displayed.
To change the setting press .
Press to enable the Exit-delay beep, or
Press to disable the Exit-delay beep.
PARTIAL ARM 2 SETUP
Scroll through the programming menu until ‘7. PARTIAL ARM 2’ is displayed
and press .
Note: After configuring Partial Arm 2 press to return to the top level
programming menu.
ENEN
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro HA68S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro HA68S in the language / languages: English as an attachment in your email.

The manual is 3,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro HA68S

Elro HA68S Quick start guide - English - 1 pages

Elro HA68S Quick start guide - German - 1 pages

Elro HA68S User Manual - German - 34 pages

Elro HA68S Quick start guide - Dutch - 1 pages

Elro HA68S User Manual - Dutch - 34 pages

Elro HA68S Quick start guide - French - 1 pages

Elro HA68S User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info