directly above a heat source, (e.g. fire, radiator, boiler, etc). Where possible, mount the detector in the
corner of the room so that the logical path of an intruder would cut across the fan detection pattern.
PIR detectors respond more effectively to movement across the device than to movement directly
towards it. Where possible, mount the detector in the corner of the room so that the logical path of an
intruder would cut across the fan detection pattern.
A
Less Sensitive More Sensitive A 1=6, 2=9,3=12m
Carefully drill out the required mounting holes in the rear cover; A. Using the rear cover as a template,
mark the positions of the fixing holes on the wall. Fix the rear cover to the wall. Detection area is
adjustable up to 12 meter; you can move the PCB up or down. Check again if Dip 4 of SW3(dipswitch
1-5) in Off. In test mode the PIR will send after every trigger a signal. In the regular mode the PIR will
pause 2 minutes, and then send again a signal after being triggered, to save batteries.
Programming the Alarm Panel:
We advise to do the programming before mounting the Alarm Panel. First we change from the Walk Test
mode to the Program/Install mode. Press until you see in the display: DISARM READYand the
time! Now we go into the Program/Install mode; mentioned further Inst. mode:
Press , 1 2 3 4 (1 2 3 4 standard Master Password), display show 1.USER SETUP.
First we will change the Master Password! Press : 1-1 USER 1 SETUP. Press
display: 1-7 MASTER SETUP, Press , display: :1 Password 1234 , Press , display:
Enter Password Code: NOW PRESS YOUR NEW CODE! and , display: :1 Password ???? .
Check if ???? is the password you entered. If ok, press 2x ,display: 1. USER SETUP, Press
display: 1-1 USER 1 SETUP, Press , display: :1 Password. Press , display: Enter
Password Code: NOW PRESS THE CODE FOR USER 1 and , display : will show the
Password you entered, CHECK! After the password
Next step is that we define some standard settings, per sensor ; press until you see in the
display:
1. USER SETUP. Press ,until in display: 3. ZONE SETTING. No we can choose:
Zone Setup (Z1-10) ; fill in the Zone Number you defined in the sensors!
Select all the zones you defined in the sensors!
Name
No Name
You can select a room name, or leave ‘no name’
Type
Intruder
Normal sensor will be ‘intruder’.
Final Exit
OFF
‘OFF’
Chime
OFF
‘OFF’
Entry Delay Zone 1
Zone 2-10
ON, 30s
OFF
Depends if you have to pass the
when you leave, or come back!
Part-Arm 1
OFF
Do you want switch this sensor on in PARM1
Part-Arm 2
OFF
Do you want switch this sensor on in PARM2
Walk Through
OFF
‘OFF’
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AP5500 - Pro Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AP5500 - Pro Alarm System in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System User Manual - English - 49 pages

Elro AP5500 - Pro Alarm System Quick start guide - German - 10 pages

Elro AP5500 - Pro Alarm System Quick start guide - Dutch - 8 pages

Elro AP5500 - Pro Alarm System User Manual - Dutch - 42 pages

Elro AP5500 - Pro Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info