Indicator
PCB Position
PCB Board
Dip Switches
TEST MODE WALK TESTis displayed.
Press to activate Walk Test. Walk Test Waiting…’ is displayed. Press the ARM button
on the Remote Control; Alarm Panel will beep and the type of the device and button will be on the
display. Press the other buttons on the Remote, as each button is pressed the Alarm Panel will beep
and show the button being pressed on the display. KEEP THE ALARM PANEL IN THE TEST MODE!
PIR Motion Sensor:
PIR Sensors are designed to detect movement.
Insert the 9 Volt battery. The PIR will warm-up during 2-3 minutes. The LED will flash. When it is ready
the LED stops. First check the house code: SW2; switch 1 8 (must be same as Remote Control). You
can divide your detectors over your total home in zones. You can set the alarm zone the PIR detector
will operate on, by switch the dip switches 1, 2 and 3 (of SW3; dipswitch 1-5) in the position according
schedule above. Mark which zone number on the PIR. For walk test mode you put dip 4 of SW3 On.
Dont forget to put back in Off. Test the PIR in the walk test mode. In normal mode the PIR will only send
a mew signal after being triggered after 2 minutes
The PIR sensor incorporates an anti-false alarm for where the Sensor might be affected by e.g. insects,
air temperature etc. We recommend high sensitivity, but in case of affection of (e.c. insects) , you can
adjust dip 5 of SW3 to Off: low sensitivity detection!
Door/window magnet:
The Magnetic Contact consists of two parts; a Detector and a Magnet. They are designed to be fitted
to doors or windows with the Magnet mounted on the moving/opening part.
Mounting the door/wind magnet:
Decide which doors/windows are to be protected by fitting Magnetic
Contact Detectors, (usually the front and back doors. Additional detectors
may also be fitted where required to other vulnerable doors or windows,
(e.g. garage, patio/conservatory doors etc).Ensure that the position selected
for the Magnetic Contact detector is within effective range of the Control Panel, (refer to
‘Testing the Control Panel & Remote Control’). Remove the battery holder, and mount the
detector using either the adhesive tape or screws. Fit the Magnet to the moving part of the door/window
opposite the Detector. Ensure that the parallel gap between the Magnet and Detector is less than 10mm
and that the arrow on the Magnet is pointing towards and aligned with the mark on the Detector.
Mounting the PIR motion sensor:
Household pets should not be allowed into an area protected by a PIR detector! Do not locate the
detector facing a window facing direct sunlight. PIR Detectors are not suitable for use in
conservatories. Do not locate the detector where it is exposed to ventilators. Do not locate the detector
DIP 1 DIP 2 DIP 3
Zone 1 OFF OFF OFF
Zone 2 OFF OFF ON
Zone 3 OFF ON OFF
Zone 4 OFF ON ON
Zone 5 ON OFF OFF
Zone 6 ON OFF ON
E
1 2 3
Open the sensor, take out the battery
connector, and place the battery! Check the
house code; same as PIR and Remote Dip 1-
8 from 1-12. Select the Zone you want: setting
Dip 9-11 according the overview at the PIR.
Mark the Zone number on the magnet.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AP5500 - Pro Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AP5500 - Pro Alarm System in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System User Manual - English - 49 pages

Elro AP5500 - Pro Alarm System Quick start guide - German - 10 pages

Elro AP5500 - Pro Alarm System Quick start guide - Dutch - 8 pages

Elro AP5500 - Pro Alarm System User Manual - Dutch - 42 pages

Elro AP5500 - Pro Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info