2.1 Changing of Personal Code
1. Type in the access code that is to be changed. The buzzer beeps
twice to confirm that it is correct, otherwise it indicates an error with a
long beep.
2. Press the
C
**
key. The message «INSERT NEW CODE» appears
on the display.
3. Enter the new code. The message «RE-INS NEW CODE» appears
on the LCD display.
4. Enter the new code a second time.
If the new code has been correctly entered, it is accepted and this is
confirmed when the buzzer beeps twice; otherwise, an error warning
is given and the procedure is exited.
Example of code change
- The Master user wishes to change the factory code 1-11111.
- Type in 111111 on the keypad and press the
C
**
key. The message
“ENTER NEW CODE” appears on the display.
- Enter the new code, for example, 165744. The message “RE-ENTER
NEW CODE” appears on the LCD display. Now re-type the numbers
165744.
- The buzzer beeps twice to confirm acceptance of the new code.
1. Enter the MASTER User code.
2. Press the
F
key and then the
C
**
key. The message “ENABLE
CODE” appears on the display.
It is now possible to enable/disable the engineer’s code, the
telemonitoring code, the User 2 code and the key code. These 4 codes
are associated with the 4 leds present on the keypad:
ENGINEER
TELEMONITORING
USER 2
KEY CODE (EK)
3. Press the key next to the led to enable/disable the corresponding
code
4. Press the
EXIT
F
key to exit the procedure.
Note: the first number
of the code must be the
user’s identification
number:
1 for the Master user
2 for User 2
3 fo r the engineer
4 for telemonitoring
5 for User 5
6 for User 6
7 for User 7
8 for User 8.
2.2 Enabling/Disabling of the User 2,
Engineer’s, Telemonitoring and Key Codes
The key code cannot be
changed: when enabled, it
allows use of the electronic
keys and of the commutators.
When disabled, it prevents
the operation of all the
commutators and of existing
keys (only system status will
be displayed by the
commutators’ leds).
KEY
CODE
The leds respectively indicate the
status of codes
Led ON = Code enabled
Led OFF = Code disabled
5
3.
Arming/Disarming
Commutator leds 1 (zone 1), 3 (zone 2) and 4 (zone 3) indicate the
system’s current status:
ON = armed zones
OFF = disarmed zones
1. Insert the commutator key and leave it inserted.
2. If the key inserted controls only one of the three zones, the status of
the zone for which the key operation is enabled changes immediately.
3. If the key controls more than one zone, the system cyclically indicates
the possible combinations that can be applied for a maximum of 4
times.
If the key controls two zones, the system displays the following
sequence:
If the key controls all three zones, the system offers the following
sequence:
Removal of the key with one of these combinations set causes
permanent arming of the selected mode and triggers the exit delay
procedure (when programmed). With the key permanently inserted,
at the end of the fourth cycle, the system exits the procedure and
remains in the previous mode.
ON = ZONE 1 ARMED
OFF = ZONE 1 DISARMED
ON = ZONE 2 ARMED
OFF = ZONE 2 DISARMED
ON = ZONE 3 ARMED
OFF = ZONE 3 DISARMED
1 1 ON - 3 ON removal of key arms both zones
2 1 ON - 3 OFF removal of key arms zone 1
3 1 OFF - 3 ON removal of key arms zone 2
1 1 ON 3 ON 4 ON removal of key arms all three zones
2 1 ON 3 OFF 4 OFF removal of key arms zone 1
3 1 OFF 3 ON 4 OFF removal of key arms zone 2
4 1 ON 3 ON 4 OFF removal of key arms zones 1 and 2
5 1 OFF 3 OFF 4 ON removal of key arms zone 3
6 1 ON 3 OFF 4 ON removal of key arms zones 1 and 3
7 1 OFF 3 ON 4 ON removal of key arms zones 2 and 3
36
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110TG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110TG in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110TG

Elkron MP110TG User Manual - German - 32 pages

Elkron MP110TG User Manual - French - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info