741486
4
Zoom out
Zoom in
Previous page
1/20
Next page
(((ELKRON)))
MP110 USER MANUAL
(((ELKRON)))
MP110 USER MANUAL
4. To disarm the system, insert the key and remove it when the leds go
OFF.
Recognition of Key with Masked System
When the system is masked, all the commutator leds are OFF.In this
way it is impossible to know whether the system is armed and masked
or actually turned OFF.
The insertion of a key with valid code causes all four commutator leds
to light up for 0.5s. This indicates that the key code has been correctly
readand is followed by the display of system mode for 3.5 seconds.
Removal of the key before this time has expired causes the system to
return to the masked mode; leaving the key inserted enables a change
in system mode like the one that took place with the arming/disarming
procedure by electronic key.
While the commutators always mask system mode, the keypads only
perform masking if the unit is armed. When OFF, all data is visible as
if the system were unmasked.
Code Recognition with Masked System
With masked system, all keypad leds are off, except for the mains led.
In this way it is not possible to know whether the system is armed and
masked or it is really off.
By entering a valid code the keypad being used visualizes the plant
status for one minute: within this period it is possible to operate.
After 1 minute from the introduction of the code, the system is masked
again.
37
2.Access Codes
The unit can be programmed so as to enable User 2 (e.g., service
personnel, custodian, porter , telemonitoring, private vigilance, etc)
to have his own secret access code which allows him to arm/disarm
the unit without performing other operations.
The unit identifies up to a maximum of 8 different assigned codes and
as many users:
After entering a correct code that is enabled, the unit’s buzzer beeps
twice, or it beeps once at length to indicate an error. The Master user’s
code is always enabled; the other codes must instead be enabled (refer
to par. “Code Enabling”).
If the engineer’s code is enabled, it remains enabled until the Master
user’s code is again entered to partially or totally arm the system, or
until the first arming by electronic key-
Once armed, every re-entry/EXCLUDED display procedure triggers a
1-minute delay (that is reset each time the key is pressed). If a delay
time-out occurs, the procedure is exited automatically without saving
the changes made.
The pressing of each key whileentering the secret code causes an
asterisk to be displayed.
FACTORY
CODE
CODE 1 - MASTER USER 1 11111
CODE 2 - USER 2 2 22222
CODE 3 - ENGINEER 3 33333
CODE 4 - TELEMONITORING 4 44444
CODE 5 - USER 5 5 55555
CODE 6 - USER 6 6 66666
CODE 7 - USER 7 7 77777
CODE 8 - USER 8 8 88888
Each user is assigned and “identification
number “ (from 1 to 8) that is to be typed in
before the code; this number allows the unit to
identify the user of the system. To be identified
by the system, the owner must type in the
number 1 followed by his personal code; any
other users will instead type in the number 2,
3, 4, 5, 6, 7 or 8, followed by his personal code
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110M in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110M

Elkron MP110M User Manual - German - 32 pages

Elkron MP110M User Manual - French - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info