STEP 2 Board initialization
1. Before proceeding set the following parameters in the Control Unit:
Master Menu ENABLE ADVANCED REMOTE ACCESS = ENABLE
Master Menu ENABLE ADVANCED REMOTE UNSETTING = ENABLE
Installer Menu MAINTENANCE USAGE MODE = MODE 2 or MODE 0
Installer Menu PROGRAMMING SECTORS CONFIGURE SECTORS = STANDARD or
SELF-INHIBITION *
* Operation to be performed on all sectors present.
2. Install the Hi-Connect software (version 3.70 or later) on a PC. To install it, follow the procedure
described in the manual “Hi-Connect Installation and Management”.
WARNING! Windows XP operating system is not supported.
3. Connect the Web server LAN cable directly to the PC.
4. Prepare and set the PC by changing the parameters of the Ethernet card used. Proceed as follows:
a) Select "Start" and type: Control panel
b) A window opens, select “Control panel
c) From "Control panel" select "Network and sharing centre" Note: Make sure that the item
View by:” is set to “Small icons
d) From "Display active networks" select the network displayed in "Connections":
e) A window with the information on the network opens, select "Properties"
f) A window with the network properties opens, double click on "Internet protocol version 4
(TCP/IPv4)".
g) Select “Use the following IP address” and, in “IP address”, type: 192.168.1.10 and in “Subnet
mask”: 255.255.255.0
5. Run the Hi-Connect software (PWD:123456).
6. After logging in, the main window of Hi-Connect menus opens.
Click on “INITIALISE IT500WEB”.
Note: Before proceeding, it is necessary to identify an IP address and the Gateway to assign to the
Web Server. This information can be identified by connecting to the router (e.g. using the Wi-Fi
connection of your PC), where the Web Server will be installed, using the IPCONFIG command.
Proceed as follows:
a) Select "Start" and type: CMD
b) A window opens, select “Command prompt
c) A window opens, type: IPCONFIG and press “Enter
d) The list of the active connections and relevant network parameters is displayed
e) Identify the network parameters (e.g. Wireless LAN card…)
f) For the Web Server, use the IP Address previously identified and increase it by a few
units (e.g. displayed IPv4 Address = 192.168.8.18; Web Server IP Address = 192.168.8.98)
g) For the Web Server, use the default Gateway previously identified
(e.g. displayed default Gateway = 192.168.8.1; Web Server default Gateway = 192.168.8.1)
7. Enter the data prompted by the wizard, those marked with an asterisk are mandatory. Continue by
clicking onNEXT” until the “INITIALISING COMPLETED!” window is displayed.
8. The same screen displays two filled-in fields specifying the MAC Address and the ID Code of the
initialised Web Server.
9. Use “COPY” to save the two codes in a file editor (Word or other), as they are essential for
subsequent registration on the WEB Portal (www.myelkronhome.com)
10. Continue by clicking on “END”.
11. A window with “Save changes made?” is displayed. Select “YES” to save the data.
WARNING! If NO is selected, the data entered in Hi-Connect will be lost, but the Web
Server will be configured with the data entered.
Note: The factory IP address of the Web Server is 192.168.1.100.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron IT500WEB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron IT500WEB in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info