3.4 CONTINUOUS SYSTEM STATUS INDICATOR
If enabled using DIP A2, the siren can view the continuous system status condition using the system status LED.
To view the system status, it is necessary to connect the TC terminal to the alarm control panel.
To enable the system status static indication, position the DIP A2 in the OFF position.
To invert the operating logic, set DIP B2 in the OFF position.
3.5 CONNECTION TO THE ALARM SYSTEM
The siren has 2 terminals (+ and -) for powering and charging the battery, an alarm control input terminal (ALL),
a system status input terminal (TC) and two tamper output insulated terminals (24H).
There are many possible connections, according to functional requirements. The alarm siren can be controlled
from a simple two-wire connection (without balancing with positive drop) up to the six-wire connection (two for
the power supply, one balanced for the alarm, one balanced for on/off, two for the 24-hour line of the control
panel).
3.6 ALARM SIGNALLING
The unbalancing of the ALL alarm input causes the alarm to sound. During the alarm, the siren sounds at high
intensity and the 4 central LEDs flash.
The alarm cycle is limited to 4 or 8 minutes, which can be selected via DIP A4. The alarm cycle is
interrupted if the ALL input goes back to rest before the set time.
The siren carries out a maximum of 8 alarm cycles. When this number is reached, the siren is
automatically blocked. The counter is reset to zero each time the system is switched on (OFF>ON)
(terminal TC) or 24 hours after the last switch on.
System status LED
System status
1 blink every second
system on
LED off
system off
4 central LEDs
(high brightness)
Horn
(high volume)
System status
continuous flashing
type “Aor “B” sound
alarm in progress
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron HPA800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron HPA800 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info