DS80IM41-001B 7
ENGLISH
The DT600 is a dual technology detector for exterior use with a curtain effect and passive infra-red (PIR) and microwave motion
sensor capable of detecting movements in an assigned area and indicate them to the control panel to activate the intrusion alarm.
The base of the product has holes to allow installation on a flat surface, using - if necessary - the 90° bracket and an articulation
(optional).
Identification of the components
1. LED filter screw covers
2. Closure screws
3. Card-fastening screws
4. Lens
5. Anti-opening tamper
6. Dip Switch (never use 4 and 5: always
OFF)
7. Detector capacity trimmer
8. PIR sensitive element
9. Detector LED
10. Battery compartment
11. Learning Button
12. Internal LED for the learning operations and battery
signals
13. Jumper tamper (removal protection)
Intended to connect the removal protection (optional, not
included)
14. For future uses (do not modify the position)
Initialisation phase
This condition is activated automatically when the battery is enabled and at each opening/closure of the front panel. It will remain
in this mode for 60 seconds, during which the detector is not active.
Test mode (Walk Test)
By opening the front panel of the sensor, after having waited for the initialisation phase to finish, the Test Mode is launched and
lasts about 4 minutes. In this condition the cut-off time is disabled, while the LED of the detector of the alarm signal is automatically
enabled.
When in this mode, the detection tests can be conducted to verify the alarms by turning on the LED and the radio connection
capacity can be tested (for details, consult the manual for the control unit). After 4 minutes, the sensor will automatically revert to
operating condition. If the front panel is reopened, the test mode (Walk Test) will be automatically reactivated, after the initialisation
time.
Cut-off time and low-consumption operation
To avoid high consumption of the battery, the detector automatically inhibits consecutive alarm signals for a set cut-off time. In
this way, the continuous movement in front o fa detector will not deplete the battery uselessly. Then between one alarm and the
next one there will be a period of silence equal to the cut-off time. This feature is not enabled during the test mode (Walk Test).
There is a choice of two cut-off times:
- Dip Switch N° 2 in OFF position 4 min (Default)
- Dip Switch N° 2 in ON position 8 min
Supervision Function
When the detector is in normal functioning mode, it periodically conducts a self-diagnostic test, transmitting a random
supervision signal every 30-50 minutes.
1
2
4
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron DT600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron DT600 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron DT600

Elkron DT600 Quick start guide - English, German, French, Italian - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info