649907
22
Zoom out
Zoom in
Previous page
1/76
Next page
22
This appliance is marked according to the European directive
2012/19/EC on Waste Electrical and Electronic Equipment
(WEEE). By ensuring this product is disposed of correctly, you will
help prevent potential negative consequences for the environment
and human health, which could otherwise be caused by
inappropriate waste handling of this product.
The symbol
on the product, or on the documents
accompanying the product, indicates that this appliance may not
be treated as household waste. Instead it should be taken to the
appropriate collection point for the recycling of electrical and
electronic equipment. Disposal must be carried out in accordance
with local environmental regulations for waste disposal.
For further detailed information regarding the process, collection
and recycling of this product, please contact the appropriate
department of your local authorities or the local department for
household waste or the shop where you purchased this product.
Appliance designed, tested and manufactured according to:
• Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.
• Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO
5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3; ISO
3741; EN 50564; IEC 62301.
• EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2;
EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a correct
use in order to reduce the environmental impact: Switch ON the
hood at minimum speed when you start cooking and kept it
running for few minutes after cooking is finished. Increase the
speed only in case of large amount of smoke and vapour and use
boost speed(s) only in extreme situations. Replace the charcoal
filter(s) when necessary to maintain a good odour reduction
efficiency. Clean the grease filter(s) when necessary to maintain a
good grease filter efficiency. Use the maximum diameter of the
ducting system indicated in this manual to optimize efficiency and
minimize noise.
Use
The hood is designed to be used either for exhausting or filter
version.
Ducting version
In this case the fumes are conveyed outside of the building by
means of a special pipe connected with the connection ring
located on top of the hood.
Attention! The exhausting pipe is not supplied and must be
purchased apart.
Diameter of the exhausting pipe must be equal to that of the
connection ring.
Attention! If the hood is supplied with active charcoal filter, then it
must be removed.
Connect the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller
dimensions will cause a diminution of the suction performance and
a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum elbow
angle: 90°).
! Avoid drastic changes in the duct cross-section.
Filter version
The aspirated air will be degreased and deodorised before being
fed back into the room.
In order to use the hood in this version, you have to install a
system of additional filtering based on activated charcoal.
The models with no suction motor only operate in ducting mode,
and must be connected to an external suction device (not
supplied).
The connecting instructions are supplied with the peripheral
suction unit.
Installation
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the range
hood must be not less than 40cm from electric cookers and 60cm
from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating indicated
on the plate situated inside the hood. If provided with a plug
connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after installation.
If it not fitted with a plug (direct mains connection) or if the plug is
not located in an accessible area, after installation, apply a double
pole switch in accordance with standards which assures the
complete disconnection of the mains under conditions relating to
over-current category III, in accordance with installation
instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that the
mains cable is correctly assembled.
The hood is provided with a special power cable ; if the cable is
damaged, request a new one from Technical Service.
Mounting
Very heavy product; hood handling and installation must be
carried out by at least two persons.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must verify
suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take the
weight of the hood. Do not tile, grout or silicone this appliance
to the wall. Surface mounting only.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elica Loop at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elica Loop in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info