APPENDICES
25
D LOCATION TERMINAL
D.1 Terminal location with vertical exhaust (B11)
Distance Exhaust 1,2 of 3
At the same roof level > 6m *
At a different roof level > 3m * & **
On a lower wall > 2m *
On a higher sloping surface > 6m ***
Distance” = minimum distance required to position the exhaust
in order to prevent adverse e ects in relation to;
1. A ventilation opening of a used room, toilet or bathroom
2. Supply of heated air when the supply flows through a used
room.
3. A window that can be opened and located in the vicinity of
a used room, toilet or bathroom.
* If the required distance is not feasible, the rules regarding the exit
position have priority.
** If the exhaust is placed at least one meter higher than the inlet
opening, or a window that can be opened.
*** If the required distance is not feasible, the exhaust must be placed at
least one meter above the highest façade / roof.
(4) The terminal may not be placed closer than 300 mm to an opening in
the building such as a window frame.
P
Q
Q
Q
C
D,E
A
B
J
J
F
I
Q
N
M
K
H
H
Figure D.1 - Terminal Location
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Element4 Cupido 60 CF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Element4 Cupido 60 CF in the language / languages: English as an attachment in your email.

The manual is 8,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Element4 Cupido 60 CF

Element4 Cupido 60 CF User Manual - English, German - 56 pages

Element4 Cupido 60 CF Installation Guide - Dutch - 36 pages

Element4 Cupido 60 CF User Manual - Dutch, French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info