INSTALLATION MANUAL
5 INSTALLATION PREPARATION AND - INSTRUCTION
The device is developed, tested and approved conform the
applicable standards for the usage, the performance and safety
of the product. The installation of your device must apply to
the current building prescriptions. We advise to make use of
a qualified gas installer for the installation of your device. The
installer can provide you with all information regarding the
safety regulations of the installation.
5.1 Relevant norms and guidelines
The installation must be carried out in accordance with the
following regulations
Department of the Environment, the Building Standards
(Scotland) (Consolidation) Regulations issued by the
Scottish Development Department.
BS 5440 part 1
BS 5871 part 2
BS 6891.
In the Republic of Ireland the installation must also conform to
the relevant standards, particularly in regard to flue sizing and
ventilation. Refer to documents;
IS813
ICP3
IS327
Any other rules in force.
This appliance must be installed in accordance with the rules
in force and used only in a su iciently ventilated space, and is
intended for use on a gas installation with a governed meter.
5.2 Attention points gas fireplace
This device can be place in a new or existing situation. The device
can be installed in a fully enclosed or mechanically ventilated
room without extra ventilation.
Before installation of these appliances, the area into which the
fire is to be fitted must be cleared of all debris (including dust), in
particular combustible material.
5.3 Attention points gas connection
The gas connection should apply to the local norms in force.
Calculate the diamater of the gas flue, such that no pressure loss
is occuring in the pipes. Place a shut-o valve in the near vicinity
of the device. Position the gas connection, such that it is always
accessible for service purposes.
Put the gas block and receiver behind the included service hatch.
Make sure that it is always accessible for service purposes. (See
Figure 5-1)
5.4 Requirements flue and wall terminals
The European CE-marking for the device is only applicable to
the flue materials specified by the supplier. The device must be
installed with the stainless steel flue material US by Metaloterm/
On top. The usage of other stainless steel material is only
permitted when it has the same technical specification as the
previous mentioned systems.
Only when these materials are used a good and safe performance
can be promised by Element4.
The flue channel works as a roof terminal (B11), as well as flex
pipes in an existing channel.
Please check, whether the desired terminal complies with the
regulation for your situation (See:
APPENDIX D).
It is possible that an extra shield is necessary when the terminal
is within two meters from the ground.
5.5 The chimney
Before the chimney is installed, we advice an operation test
with the device. The chimney should be constructed from non-
combustible materials and cannot rest on the mounting frame.
Always use a chimney iron, when using bricks or cell concrete.
The chimney ventilation should meet the the local norms. A well
ventilated chimney makes sure the temperature is regulated to
ensure a proper operation of the electronics and the gasblock.
Furthermore, good ventilation helps to keep the convection air
under 85
o
C.
More on chimney construction in THE NEXT CHAPTER.
Figure 5.1 - Service Hatch (BDLE4)
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Element4 Cupido 60 CF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Element4 Cupido 60 CF in the language / languages: English as an attachment in your email.

The manual is 8,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Element4 Cupido 60 CF

Element4 Cupido 60 CF User Manual - English, German - 56 pages

Element4 Cupido 60 CF Installation Guide - Dutch - 36 pages

Element4 Cupido 60 CF User Manual - Dutch, French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info