782553
15
Zoom out
Zoom in
Previous page
1/76
Next page
TECHNICAL DESCRIPTION
The electric wall-mounted convector heater is a household appliance intended to heat air in living rooms and maintain a specified
temperature.
APPLIANCE INSTALLATION
The heater installation must strictly comply with standards and rules in force in the country.
The convector heater has a degree of protection against Class II electrical current and is splash-proof (IP24). It can be installed
in living rooms, including in Zone 2 of bathing rooms, but so that controls must not be accessible to persons taking a shower or
bath - please refer to Fig. 1.
When installing the appliance it is necessary to comply with the minimum prescribed distances from various obstacles and surrounding
objects as shown in Fig. 2.
Do not install the appliance:
џIn places with compulsory draft, which can disrupt the control settings (under natural or forced ventilation apertures, fans,
etc.).
џUnder, over and in front of sockets (rosettes), please refer to Fig. 6.
When installing the heater on locations of high altitudes take into account that it may impact the temperature of the outlet air (by
о
increasing it with about 10 C when the altitude changes with 1000 m)
Take carefully the heater out of its packaging and keep it at a conventional place for any future needs.
Place the appliance with the front side to the ground without still removing the protective styrofoam side panels (Fig. 3). Please refer to
the figures on the second page of this booklet.
Unfasten the suspension stand according to the diagram shown in Fig. 3.
The installation of the convector heater on a reinforced concrete or solid brick wall can be carried out after the stand is secured to the
wall according to Fig. 4, using the screws and dowels available in the package.
Place the appliance on the stand as shown in Fig. 5.
The convector power cord plug can be connected to a protected single phase power outlet with voltage 230 V~. The socket must be
located so that it is easily accessible after fitting the device into its working position.
It is forbidden to ground the appliance!
It is forbidden to increase the distance from the wall to the convector heater, which is secured by the suspension stand provided by the
manufacturer!
15
EN EN
All data and dimensions provided are approximate.
Model
Power / Voltage
Length W [mm]
L [mm]
1000 W / 230 V~
716 / 592
480 / 200±2
1500 W / 230 V~
916 / 688
480 / 200±2
2000 W / 230 V~
1116 / 880
890 / 480±2
2500 W / 230 V~
1366 / 1072
890 / 480±2
3000 W / 230 V~
1566 / 1216
890 / 480±2
150
59
86
230
150
W
L
Convector heater on / off
switch
Control panel
Suspension
stand
RH10N(W) /
RH01W10X-W
453
106
84
434
RHххN(W)RH01WxxX-W
RH15N(W) /
RH01W15X-W RH20N(W) /
RH01W20X-W RH25N(W) /
RH01W25X-W RH25N(W) /
RH01W25X-W
RH01W05X-W
500 W / 230 V~
400
200±2
ATTENTION!
It is recommended to keep the distance of 150 mm
between the convector and the floor of the room.
The minimum allowable floor distance to the lower end of
the convector is 60 mm. Failure to comply shall reduce the
appliance safety.
242 / 257
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eldom RH01W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eldom RH01W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 7.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info