A
g. 1 g. 2
g. 4
g. 5 g. 6
g. 7 g. 8
g. 9 g. 10
C
D
E
D
GH
I
B
B1
g. 3
D
INSTALLATION
SPOT100 H is designed for the connection of the
ue at the top, back or side of the stove.
The stove is delivered ready for the ouput of the ue
from the back ( g. 1).
FOR THE CONNECTION OF THE SMOKE
OUTPUT TO THE CHIMNEY, WHETHER FROM
THE BACK, SIDE OR TOP, IT IS NECESSARY
TO REMOVE THE LEFT SIDE.
- Loosen (by about 15 mm) the two screws on the
cast iron top under the steel cover (A - g. 2).
- Open the door and remove the galvanised panel
(B1 - g. 3)
- Loosen the screw on the lower/front part of the
right and left sides (B - g. 3).
- Remove the screw above the top (see g. 5 on
page 208)
- Remove the metallic left side), moving it about 2
cm towards the front of the stove, extracting it rst
from below and then pulling it out from under the
top ( g. 4).
At this point, choose the necessary ue connection.
REAR SMOKE OUTPUT CONNECTION
Connect the rear smoke output pipe (not provided)
to the smoke extractor unit vent (C- g. 5) with the
band provided.
In this case it is su cient to make the smoke output
pipe (not provided) pass through the hole in the lo-
wer part of the sheet metal back ( g. 5).
LEFT SIDE SMOKE OUTPUT CONNECTION
Fit the elbow joint to the smoke extractor unit vent
(D- g. 6) with the band provided.
Connect the side smoke output pipe (not provided)
to the aforementioned elbow joint.
Remove the pre-cut diaphragm from the sheet me-
tal side to allow the smoke output pipe (not provi-
ded) to pass through ( g. 6).
Complete the operation by applying the closure ro-
sette provided (E - g. 7) using the screws provided,
after replacing the metal side.
N.B. The rosette and the metal side must be tted
after the ue has been de nitively xed.
TOP SMOKE OUTPUT CONNECTION
Fit the elbow connection to the smoke extractor unit
vent (D g. 8) with the band provided.
Connect the smoke output pipe (not provided) to the
aforesaid elbow joint.
In this case, it is necessary to use the two sheet
metal half-covers provided (G - H - g. 9), instead
of the whole sheet metal cover, and to eliminate the
galvanised cap (I - g. 8).
Remove the diaphragm from the small metal half-
cover (G - g.9) to allow passage of the pipe.
AFTER COMPLETING THE CONNECTION OF
THE SMOKE OUTPUT PIPE TO THE FLUE,
REPLACE THE LEFT METAL SIDE AND THEN
CONTINUE WITH THE APPLICATION OF THE
CASING.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EK63-EdilKamin Spot 100H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EK63-EdilKamin Spot 100H in the language / languages: English as an attachment in your email.

The manual is 2.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EK63-EdilKamin Spot 100H

EK63-EdilKamin Spot 100H Usermanual and installation guide - German - 32 pages

EK63-EdilKamin Spot 100H Usermanual and installation guide - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info