8.4 Check the oil level at regular intervals
Place the compressor on a level and straight sur-
face. The oil level must be between the two marks
MAX and MIN on the oil oil level window (Fig. 10).
Changing the oil: Recommended hydraulic oil:
SAE 5W/40 or an alternative of the same quality.
It should be re lled for the rst time after 10 hours
of operation. Thereafter the oil should be drained
and re lled after every 100 hours in service.
8.5 Changing the oil
Switch o the engine and pull the mains plug out
of the socket. After releasing any air pressure you
can unscrew the oil drainage screw (15) from the
compressor pump. To prevent the oil from running
out in an uncontrolled manner, hold a small metal
chute under the opening and collect the oil in a
vessel. If the oil does not drain out completely, we
recommend tilting the compressor slightly.
Dispose of the old oil at a drop-o point for
old oil.
When the oil has drained out, re- t the oil draina-
ge screw (15). Fill new oil through the oil ller ope-
ning (13) until it comes up to the required level.
Then replace the oil sealing plug (14).
8.6 Cleaning the intake lter (1)
The intake lter prevents dust and dirt being
drawn in. It is essential to clean this lter after at
least every 300 hours in operation. A clogged
intake lter will decrease the compressor‘s per-
formance dramatically. Undo the screw on the
air lter so that the halves of the air lter housing
can be opened. Use compressed air at low pres-
sure (approx. 3 bar) to blow out all the parts of
the lter and then assemble the lter in reverse
order. When cleaning, take adequate precautions
against dust (e.g. use a suitable face mask).
8.7 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch o the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry location.
Always store upright, never tilted!
8.8 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
9. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council o ces.
Anl_TC_AC_190_24_SPK1.indb 19Anl_TC_AC_190_24_SPK1.indb 19 06.08.14 14:4106.08.14 14:41
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell TC-AC 190-24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell TC-AC 190-24 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell TC-AC 190-24

Einhell TC-AC 190-24 User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info