3. Proper use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: ......................... 230 V ~ 50 Hz
Motor rating: ........................... 1500 W S2 15 min
Compressor speed min
-1
: ............................ 2850
Operating pressure bar: ............................max. 8
Pressure vessel capacity (in liters): ................. 24
Theoretical suction rate l/min.: ...................... 160
Output (compressed air) at 7 bar: ....60 liters/min
Output (compressed air) at 4 bar: ....76 liters/min
Sound power level L
WA
in dB: ........................... 97
K
WA
uncertainty: ........................................... 3 dB
Protection type: ............................................IP20
Weight of the unit in kg: ............... approx. 19,5 kg
Oil quantity: ............................... approx. 0.2 liters
Noise
The noise emission values were measured in ac-
cordance with EN ISO 2151.
5. Before starting the equipment
Warning!
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines (ex-
tensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
The oil level in the compressor pump has to
be checked before putting the equipment into
operation.
The equipment must be set up where it can
stand securely.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the rst time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 5.
6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in
Fig. 6.
6.3 Replacing the oil sealing plug (14)
Remove the transportation cover from the oil ller
opening with a screwdriver and insert the sup-
plied oil sealing plug (14) into the oil ller opening
(Fig. 7).
Anl_TC_AC_190_24_SPK1.indb 17Anl_TC_AC_190_24_SPK1.indb 17 06.08.14 14:4106.08.14 14:41
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell TC-AC 190-24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell TC-AC 190-24 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell TC-AC 190-24

Einhell TC-AC 190-24 User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info