16
GB
11. Troubleshooting
Device does not start. Check the following:
1. Is voltage present at the plug socket outlet?
2. Check the plug fuse!
3. Is the timer set?
The device does not provide satisfactory cooling!
Check the following:
1. Has an appropriate temperature been set?
2. Is the air filter soiled? Clean and fit back in place.
3. Are the inlets and outlets on the outdoor device
blocked?
4. Has the sleep mode been set during the day?
5. Are the connections between the indoor and
outdoor device adequately sealed? There may not
be enough coolant? If so, please contact your
service company.
In the event of a power failure, check the
following:
Press the ON/OFF key after a power failure. If the
problems remain after checking through the above
points, switch off the device and contact your service
company.
12. Installation accessories
Please check that all the installation accessories
have been supplied prior to carrying out the
installation work.
1 mounting plate for the indoor device
1 infrared remote control
2 batteries (type AAA, 1.5 V)
10 screws (4.2 x 25)
1 condensed water hose (L = 2 m)
1 sealing compound
1 wall hole cap
5 cable ties
13. Installation instructions (Fig. 14):
Check that the actual mains voltage is the same
as the mains voltage specified on the rating
plate.
앬 Important. Make sure that there are no electric
cables or other installations (for example water
pipes) near the drill holes.
앬 Earth the outdoor device in accordance with
current regulations.
앬 The device must have separate protection
against short-circuits.
앬 Leave the electrical installation work (230 V
socket-outlet) to a specialist contractor.
앬 Have all refrigeration installation work performed
by a specialist contractor if you are not confident
of doing this yourself.
앬 Incorrect installation can lead to injury or damage
to property.
앬 Always wear ear muffs, goggles and work gloves
when performing work of installation.
Notes on electrical connection!
All electrical connection work (230 V socket-outlet
)
must be performed by a qualified electrician
authorized to do so such work by the applicable
electricity supply company. The system must have
separate protection against short-circuits. Select a
suitably large cable cross-section. The yellow/green
wire is to be used as a protective conductor only and
under no circumstances as a voltage carrying
conductor. The fixed electrical connection of the
device must be capable of being isolated from the
mains power supply by a device with an isolating
distance of at least 3 mm (e.g. circuit-breaker).
Connect the electrical connections of the indoor and
outdoor devices together first and then connect to
the mains power supply. Check first that the entire
system is voltage-free. Secure the system from being
switched on again.
A. Selecting the place of installation
Indoor device
1. The openings for the inlet and outlet air must
never be covered, otherwise the air will not be
distributed throughout the entire room.
2. Install the indoor device in a location which
ensures that the distance through the wall to the
outdoor device is as short as possible.
3. Make sure that the drainage hose does not have
any kinks or upward inclines when you connect it
with the outside.
4. Do not select a location adjacent to a source of
heat, high humidity or inflammable gas.
5. Select a location which is firm enough for
installation so that the device is not subjected to
vibrations.
6. Check that the device has been installed
correctly and exactly.
7. Make sure that there is sufficient space available
for later repair and service work.
8. The device should be installed at a distance of at
least 1 m from all other electrical devices and
installations, e.g. TV, radio, computer, etc.
9. Select a location for the device which is easily
accessible so that the filter can be cleaned or