10
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device:
20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature:
7°C for dry thermometer bulb (DB), 6°C for wet
thermometer bulb (WB).
Temperature ranges:
Cooling
Room temperature 16°C ~ 30°C
Outdoor temperature > +18°C
Heating
Room temperature 16°C ~ 30°C
Outdoor temperature > 0°C
Dehumidifying
Room temperature 16°C ~ 30°C
Outdoor temperature > +18°C
Notes:
1. For health reasons the room temperature should
be no more than 5 – 6°C below the outdoor
temperature in cooling mode.
2. The perfect performance of the system is
achieved within the temperature ranges shown in
the table.
3. If the air conditioning system is operated below
the temperature range shown above, protection
functions may be activated in certain
circumstances which will cause the device to
operate abnormally.
4. If the air conditioner is operated in a relative
humidity level of over 80%, condensation may be
deposited on the top of the system which will
then drip on to the floor. In this case set the
horizontal air flap to its maximum angle
(perpendicular to the floor) and set the FAN to
“HIGH”.
4. Intended use
The air conditioner is only designed for cooling,
heating or dehumidifying private homes or
bedrooms.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Description of parts (Fig. 1)
1 Front panel
2 Air inlet
3 Air filter
4 Air outlet
5 Horizontal air flow grille
6 Vertical air slit
7 Remote control
8 Refrigerant line, condensate hose
9 Air inlet
10 Air outlet
6. Remote control display
Explanation of “MODE” display
AUTO = Automatic
COOL = Cooling
DRY = Dehumidifying
FAN = Fan function
HEAT = Heating
Explanation of “FAN” display
Auto = Automatic fan speed
Low Fan = low fan speed
Middle Fan = middle fan speed
High Fan = high fan speed
7. Setting up the remote control
Insert batteries
1. Open the battery compartment cover.
2. Insert two new batteries. Be sure to observe the
correct polarity (+/-) of the batteries.
3. Close the battery compartment cover.
Notes
The radio signal has a range of approx. 8 m.
Use two alkali batteries, type R03 AAA (1.5 V).
Always replace both batteries at once when you
can no longer see the LCD display.
Never use a combination of new and used
Anleitung_SKA_3503_C_H_GB:_ 14.02.2008 11:37 Uhr Seite 10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 3503C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 3503C in the language / languages: English as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 3503C

Einhell SKA 3503C User Manual - German - 28 pages

Einhell SKA 3503C User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info