Fit the indoor device to the hook at the top of the
mounting plate and let it lock into place at the
bottom.
The package of lines/hoses is to be laid between
the housing of the indoor device and the wall. In
order to prevent condensation water, insulate the
package of lines/hoses with heat insulation
material.
Fit the two halves of the inside wall hole cap to
the wall hole tube.
4. Installing the outdoor device
It is imperative that you follow the installation
instructions.
4.1 Before you start installation
Select the location for installation (follow the
previous notes on selecting the location).
Check that the available mains voltage is the
same as the voltage specified on the rating plate.
The maximum distance between the indoor and
the outdoor device is restricted by the length of
the coolant tube, which is a maximum of 4m. It is
NOT possible to extend the coolant tube.
If the outdoor device is higher than the indoor
device, make sure that a curve is made in the
coolant tube which is lower than the bottom edge
of the indoor device.
Fasten the condensation water drain to the base
of the outdoor device.
4.2 Mounting the outdoor device
The outdoor device can be fastened to the
ground or to a wall bracket (e.g. special
accessory Art. No. 23.651.55) with dowels and
screws. To do so, use the holes on the device.
5. Connecting the refrigerant lines
5.1 Important information
-You will require the following tools to carry out this
installation work correctly:
1x open-ended spanner, 19 mm
1x open-ended spanner, 22 mm
1x open-ended spanner, 24 mm
1x Allen key, 5 mm
1x Philips screwdriver
1x leak detection spray or alternatively soap suds
(water / detergent mix)
Follow the detailed instructions for connecting
the refrigerant lines to the letter. We can only
provide a warranty if the lines are installed
correctly as described in the instructions.
Kinked and/or damaged lines and connectors
can only be accepted under the warranty if a
claim is made for them before the installation
work is carried out.
Do not remove the sealing caps and stoppers
until immediately before you install the lines.
To prevent leaks, ensure that the quick-release
screw connections are absolutely free of dirt.
Moisture or foreign bodies will adversely affect
the function of the quick-release connectors,
leading to a risk of refrigerant loss (not covered
by the warranty).
Only install refrigerant lines outdoors in dry
weather.
The refrigerant lines must not be installed and
then plastered over.
Please make sure that refrigerant is never
allowed to enter the environment.
Improper handling of refrigerant may be harmful
to health. Always wear work gloves and goggles
when handling refrigerant.
The equipment designed for outdoor use may
only be installed outdoors. Provide good
ventilation.
Do not smoke during the installation work.
The equipment must never be operated without
the refrigerant lines connected, otherwise the
equipment will be damaged immediately.
The screw connections may only be tightened
using the appropriate open-ended spanner.
Remember that if they are tightened with too little
torque they will leak but if they are tightened with
Hook at the top
Heat insulation
material
Wall hole cap
Hook at the
bottom
Inddor device
Outddor device
Curve
Coolant tube
Anleitung SKA 2501 EQ C+H_GB:_ 07.12.2006 14:09 Uhr Seite 25
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell ska 2501 eq c h at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell ska 2501 eq c h in the language / languages: English as an attachment in your email.

The manual is 1,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell ska 2501 eq c h

Einhell ska 2501 eq c h User Manual - German - 36 pages

Einhell ska 2501 eq c h User Manual - Dutch - 32 pages

Einhell ska 2501 eq c h User Manual - French - 36 pages

Einhell ska 2501 eq c h Additional guide - All languages - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info