13. Installation accessories
Please check that all the installation accessories
have been supplied prior to carrying out the
installation work.
1 mounting plate for the indoor device
1 infrared remote control
2 batteries (type AAA, 1.5 V)
1 condensed water hose (L = 2 m)
2 sealing compound
1 wall hole cap
2 roll of plastic wrapping tape
1 set of refrigerant lines (L = 4 m)
8 screws ST 3.9x25
8 wall plugs
1 wall passage hole
14. Installation instructions /Fig. 14):
Check that the actual mains voltage is the same
as the mains voltage specified on the rating
plate.
Use only suitable fastening material. The
supplied plugs and screws are suitable for
concrete, natural stone with a dense structure,
solid bricks, solid lime-sand blocks, solid blocks
made of lightweight concrete, pore concrete (gas
concrete), solid gypsum panels, perforated high
blocks, perforated lime-sand blocks and hollow
blocks made of lightweight concrete.
Important. Make sure that there are no electric
cables or other installations (for example water
pipes) near the drill holes.
Earth the outdoor device in accordance with
current regulations.
The device must have separate protection
against short-circuits.
Have all work of electrical installation performed
by an electrician.
Ask a service partner or specialist cooling
system firm to undertake all work of installing the
cooling system.
Incorrect installation can lead to injury or damage
to property.
Always wear ear muffs, goggles and work gloves
when performing work of installation.
Notes on electrical connection!
All electrical connection work must be performed by
a qualified electrician authorized to do so such work
by the applicable electricity supply company. The
system must have separate protection against short-
circuits. Select a suitably large cable cross-section.
The yellow/green wire is to be used as a protective
conductor only and under no circumstances as a
voltage carrying conductor. The fixed electrical
connection of the device must be capable of being
isolated from the mains power supply by a device
with an isolating distance of at least 3 mm (e.g.
circuit-breaker).
Connect the electrical connections of the indoor and
outdoor devices together first and then connect to
the mains power supply. Check first that the entire
system is voltage-free. Secure the system from being
switched on again.
A. Selecting the place of installation
Indoor device
1. The openings for the inlet and outlet air must
never be covered, otherwise the air will not be
distributed throughout the entire room.
2. Install the indoor device in a location which
ensures that the distance through the wall to the
outdoor device is as short as possible.
3. Make sure that the drainage hose does not have
any kinks or upward inclines when you connect it
with the outside.
4. Do not select a location adjacent to a source of
heat, high humidity or inflammable gas.
5. Select a location which is firm enough for
installation so that the device is not subjected to
vibrations.
6. Check that the device has been installed
correctly and exactly.
7. Make sure that there is sufficient space available
for later repair and service work.
8. The device should be installed at a distance of at
least 1 m from all other electrical devices and
installations, e.g. TV, radio, computer, etc.
9. Select a location for the device which is easily
accessible so that the filter can be cleaned or
replaced without difficulty.
10. The maximum distance between the standard
indoor unit and outdoor unit is 4 m. The
maximum possible length of the refrigerant line is
10 m with a maximum height difference of 5 m.
11. Avoid direct sunlight.
GB
18
Anleitung_NSK_3503_I_C_H_GB:_ 21.12.2007 8:33 Uhr Seite 18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell NSK 3503 I C H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell NSK 3503 I C H in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell NSK 3503 I C H

Einhell NSK 3503 I C H User Manual - German - 28 pages

Einhell NSK 3503 I C H User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info