724140
21
Zoom out
Zoom in
Previous page
1/88
Next page
GB
- 21 -
3. Proper use
The air-conditioning system is only designed
to air-condition dry rooms. The room volume
depends on the local conditions. Large window
areas, additional heat sources (PC, television,
people, etc.), poor wall insulation, etc. serve to
reduce this room volume.
The equipment is to be used only for its
prescribed purpose. Any other use is deemed to
be a case of misuse. The user / operator and not
the manufacturer will be liable for any damage or
injuries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Before starting the equipment
Before you connect the equipment to the
mains supply make sure that the data on the
rating plate are identical to the mains data.
Always place the portable device on a firm,
horizontal footing.
The machine must always be in an upright
position.
Never tilt the device by more than 45°!
Whenever the device has been transported
(inclined positions), leave for at least one
hour before connecting to a socket outlet.
In the cooling function the warm exhaust air
must be transferred outside by the exhaust air
hose. An opening in the wall or window must
therefore be provided.
Please note that the minimum distance bet-
ween the equipment and the wall to the side
50 cm and rear must be 50 cm. The minimum
distance to other objects at the front must be
2 m.
4.1 Installing the activated charcoal filter
(Fig. 4)
1. Take out the filter frame
2. Remove the filter fastener from the filter frame
3. Take the carbon filter out of the bag
4. Place the carbon filter in the filter frame
5. Fasten the filter with the filter fastener
6. Slide in the filter frame
4.2. Installing the exhaust air hose (Fig. 5)
Use only the supplied exhaust air hose. The
length of the exhaust air hose can be varied from
between 500 mm to 1500 mm. For the most
effective cooling the hose should be as short as
possible. Avoid kinks are excessive bends in the
hose so that the exhaust air can be transferred
out without hindrance. If you ignore this advice,
the device as a whole may overheat and shut
down. This could result in damage to the device.
Warning!
The length of the exhaust air hose is matched
to the technical specifications of the device.
Never extend the hose as this could lead to
malfunctions or faults on the device.
Under certain circumstances a partial vacuum
may develop in the room, which will lead to a
reduction in the cooling performance of the
device. To prevent this from happening you must
ensure that there is a supply of air to the room
(leave the door to the room slightly open).
Fitting the exhaust air hose through an open
window (Fig. 6)
Secure the exhaust air hose to the connection
opening for the exhaust air hose by turning it
clockwise.
Use the exhaust air adapter for the window
and the extendible window adapter. Fasten
the air adapter for the window to the exhaust
air hose by turning it clockwise. Open the
window slightly and clamp the window
adapter in the gap. Secure the window so
that the window adapter is kept firmly in
place. Insert the exhaust air adapter for
the window in the opening provided in the
window adapter.
Accessory:
Hot Air Stop Art.-Nr.: 23.651.50
Note: Take appropriate precautions to prevent
unauthorized entry through the window.
Fitting the exhaust air hose through the wall
We recommend that you use a suitable telescopic
duct with automatic shutter and wall connection
(available at your DIY store) to which you can
connect the hose without using the exhaust air
adapter for the window.
Anleitung_MK_2100_E_SPK7.indb 21Anleitung_MK_2100_E_SPK7.indb 21 25.09.2018 10:12:4125.09.2018 10:12:41
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell MK 2300E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell MK 2300E in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info