3. Proper use
The dehumidi er is designed only for use in pri-
vately used rooms (e.g. living rooms, bedrooms,
bathrooms, storage areas, laundry rooms or
basements).
Note:
65% humidity is the upper limit at which the hu-
man body feels comfortable. If it is too warm for
the human body, the humidity level (i.e. water con-
tent) is too high. Humidity and temperature are
interrelated. A relative humidity (RH) of 35 to 65%
at 21°C is generally considered to be ideal.
It is uneconomical to use the equipment at a room
temperature below 10°C or at a room humidity
below 40%.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
LE 16
Power supply: ..........................220-240 V ~ 50 Hz
Max. rated current consumption: ................ 1.42 A
Starting current: ............................................10 A
Max. power consumption: .......................... 285 W
Sound pressure level: ......................... 47 dB(A)
Dehumidifying capacity:
.... 0.67 l/h (at a room temperature of 30°C and air
...................................................humidity of 80%)
.... 0.34 l/h (at a room temperature of 27°C and air
...................................................humidity of 60%)
Humidity operating range: .......................... > 40%
Temperature operating range: .................5 – 35°C
Max. volumetric air ow: ............................ 180 m
3
Condensate collector capacity: ..................4 liters
Refrigerant: ................................................R134a
Greenhouse warming potential ...........................
(GWP, kg CO2 eq.) ....................................... 1430
Coolant quantity: ......................................... 160 g
Equipment dimensions:........ 316 x 316 x 536 mm
Equipment weight: .......................................13 kg
LE 20
Power supply: ..........................220-240 V ~ 50 Hz
Max. rated current consumption: ................ 1.74 A
Starting current: ............................................10 A
Max. power consumption: .......................... 350 W
Sound pressure level: ......................... 47 dB(A)
Dehumidifying capacity:
.... 0.83 l/h (at a room temperature of 30°C and air
...................................................humidity of 80%)
.... 0.42 l/h (at a room temperature of 27°C and air
...................................................humidity of 60%)
Humidity operating range: .......................... > 40%
Temperature operating range: .................5 – 35°C
Max. volumetric air ow: ............................ 180 m
3
Condensate collector capacity: ..................4 liters
Refrigerant: ................................................R134a
Greenhouse warming potential ...........................
(GWP, kg CO2 eq.) ....................................... 1430
Coolant quantity: ......................................... 250 g
Equipment dimensions:........ 316 x 316 x 536 mm
Equipment weight: .......................................14 kg
LE 30
Power supply: ..........................220-240 V ~ 50 Hz
Max. rated current consumption: ................ 2.74 A
Starting current: ............................................12 A
Max. power consumption: .......................... 550 W
Sound pressure level: ......................... 50 dB(A)
Dehumidifying capacity:
.... 1.25 l/h (at a room temperature of 30°C and air
...................................................humidity of 80%)
.... 0.64 l/h (at a room temperature of 27°C and air
...................................................humidity of 60%)
Humidity operating range: .......................... > 40%
Temperature operating range: .................5 – 35°C
Max. volumetric air ow: ............................ 260 m
3
Condensate collector capacity: ..................8 liters
Refrigerant: ................................................R134a
Greenhouse warming potential ...........................
(GWP, kg CO2 eq.) ....................................... 1430
Coolant quantity: ......................................... 290 g
Equipment dimensions:........ 386 x 386 x 662 mm
Equipment weight: ....................................15,3 kg
Anl_LE_16_20_30_SPK7.indb 14Anl_LE_16_20_30_SPK7.indb 14 24.02.16 08:3324.02.16 08:33
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell LE 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell LE 30 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info