605897
16
Zoom out
Zoom in
Previous page
1/96
Next page
GB
- 16 -
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft always must be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
The pump shaft should be large enough.
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 230 V ~ 50 Hz. Make sure that the
socket-outlet is su ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
Danger!
To rule out danger, this work must be left strictly to
a specialist electrician or Customer Service.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
230 V ~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run
dry.
To switch off the equipment, pull the power
plug out of the socket outlet.
Setting the On/O switching point:
The ON/OFF switching point of the oating switch
can be adjusted by shifting the oating switch in
the oating switch notched holder (Fig. 3/Item 5).
The floating switch must be fitted so that the
switching point height: ON and the switch
point height: OFF can be reached easily and
with little force. Check this by placing the
equipment in a container filled with water
and carefully raising and lowering the floating
switch with your hand. You can then see whe-
ther the equipment switches on and off.
Make sure that the distance between the floa-
ting switch head and the cable holder is not
too smaller than 10 cm. If the distance is too
small, there is no guarantee that the equip-
ment will work correctly.
When adjusting the floating switch, make
sure that the floating switch does not touch
the bottom before the equipment is switched
off. Important! Risk of dry running.
Manual operation:
Mount the oating switch as illustrated in Figure 1.
The equipment will then run continuously. To pre-
vent dry running, this operating mode is allowed
only under supervision. The equipment must be
switched o (pull out the power plug) as soon as
no more water is emitted from the discharge line.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_GH_DP_7835_SPK1.indb 16Anl_GH_DP_7835_SPK1.indb 16 29.07.14 11:5429.07.14 11:54
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GH-DP 7835 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GH-DP 7835 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GH-DP 7835

Einhell GH-DP 7835 User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info