3. Proper use
The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially not for engine fuels,
cleaning agents and other chemically-based
products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment’s anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.
4. Technical data
Mains connection ........................... 230 V ~ 50 Hz
Power rating ............................................... 780 W
Max. pumping rate .................................15700 l/h
Max. delivery head ......................................... 8 m
Max. submersion depth .................................. 8 m
Max. water temperature ............................... 35°C
Hose connection ....... approx. 47.8 mm (G 1½ ) IG
Max. size of foreign bodies: ....................Ø 35 mm
Switching point height: ON .....max. approx. 50 cm
Switching point height: OFF ......min. approx. 5 cm
Protection type. .............................................IPX8
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
5.1 Installation
The equipment can be installed either:
Stationary with a rigid pipe line
or
Stationary with a flexible hose line
Notice!
Before you use the pump, clarify any possible
special conditions which need to be ful lled for
the installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protec-
ted power circuit, moisture sensors for switching
o the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
The maximum pumping rate is possible only with
the largest possible line diameter; if smaller hoses
or pipes are connected, the pumping rate will be
reduced. If the universal hose connection (Fig. 1/
Item 4) is used, it should be shortened (as shown
in Fig. 2) to the connection actually used in order
not to reduce the pumping rate unnecessarily.
Flexible hoses must be fastened to the universal
hose connection with a hose clip (not included in
the scope of supply).
Anl_GH_DP_7835_SPK1.indb 15Anl_GH_DP_7835_SPK1.indb 15 29.07.14 11:5429.07.14 11:54
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GH-DP 7835 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GH-DP 7835 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GH-DP 7835

Einhell GH-DP 7835 User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info