ENGLISH
INSTALLATION
EXTERNAL COMBUSTION AIR INTAKE (A)
To restore the oxygen burnt during operation, it is
necessary to have an adequate air intake, pursuant to
local regulations, of 200 cm2.
In accordance with local regulations, the air intake can
be mounted outside or in suitable rooms not subject
to depression.
The cladding must have the grille at floor level so that
combustion air can enter the product.
DIRECT AIR INTAKE
DIRECT AIR INTAKE
Install an air intake with an effective size (net of the
mesh or other protective equipment) that is at least
equal to that of the air intake at the back of the product.
Choose the diameter based on the load losses.
Connect the air intake to the appliance's air intake with
a pipe that may also be flexible. Increase the diameter
of the pipe if the pipe is not smooth: assess any load
loss.
A maximum length of 5 metres is recommended, with
no more than 3 bends depending on the draft of the
flue.
The air maybe drawn from an adjacent room only if:
• the flow is taken from permanent, unobstructed
openings communicating with the outdoors
• the air pressure in the adjacent room is never
reduced to a level below outdoor pressure
• the adjacent room is not a garage, subject to fire
hazard, a bathroom or a bedroom
• the adjacent room is not a shared room in the
condominium.
In Italy, UNI 10683 provides that ventilation is sufficient
even if a pressure difference between the outdoors
and indoors of no more than 4 PA is guaranteed (UNI
EN 13384-1). The installer who issues the declaration
of conformity is responsible for ensuring these
conditions.
INSTALLER
(A)
(A)
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin WIDRO 85 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin WIDRO 85 in the language / languages: English as an attachment in your email.

The manual is 2.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin WIDRO 85

Edilkamin WIDRO 85 Usermanual and installation guide - German - 44 pages

Edilkamin WIDRO 85 Usermanual and installation guide - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info