810770
45
Zoom out
Zoom in
Previous page
1/209
Next page
- 45 -
ENGLISH
POSSIBLE TROUBLESHOOTING
In the event of problems the stove stops automatically and runs the shutdown process and the display shows text
regarding the motivation of the shutdown (see the various alarms below).
Never pull the plug during shutdown on account of malfunction.
Should it block, to restart the stove you will need to allow the turn-off procedure to take place (600 seconds with
audible signal), and then press the button 0/1 .
Do not turn the stove on again before checking the cause of the malfunction and CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION AND INDICATIONS AND REMEDIES:
1) Signalling: Veri c./air ow: (intervenes if the ow sensor detects insuf cient combustion ).
Problem: Turns off for lack of depression
Air ow may be insuf cient because the door is open, the door does not close properly (e.g. bad seal), there is an
air intake or smoke extraction problem, or the combustion chamber is clogged.
Actions: Check:
door closure;
• combustion air intake duct (clean, paying attention to the ow sensor components);
clean the ow sensor with dry air (like that used for PC keyboards);
• stove location: it must not be installed against a wall;
• combustion chamber position and cleanliness (clean regularly according to the type of pellet);
• smoke duct (clean);
• installation (if it does not comply with regulations or the smoke outlet has more than 2-3 bends);
If you suspect the sensor is malfunctioning, carry out cold tests. If the conditions are changed (for example by
opening the door) and the value does not change, there is a sensor problem.
N.B.: The no depression alarm may also occur during ignition, since the ow sensor starts monitoring 90 seconds after
the ignition cycle begins.
2) Signalling: Veri c./extract.: (this trips if the smoke extraction speed sensor detects a fault)
Problem: Shutdown for smoke extraction speed fault detection
Actions: • Check smoke extractor function (devolution sensor connection) and board (DEALER).
• Check smoke channel for dirt
• Verify the electrical system and earthing system.
• Check eletronic circuit board (DEALER).
3) Signalling: Stop/Flame: (this trips if the thermocouple detects a smoke temperature lower than the value set, which it
interprets as the absence of ames)
Problem: Turns off due to drop in smoke temperature
Actions: • lack of pellets
• too many pellets have suffocated the ame, check pellet quality (DEALER)
• the maximum thermostat has intervened (rare, this only intervenes in the event of excessive smoke
temperature) (DEALER)
4) Signalling: Block_FI/NO Start: (intervenes if a ame fails to appear within a maximum of 15 minutes, or if ignition
temperature is not reached).
Problem: Turns off due to incorrect smoke temperature during ignition
Distinguish either of the following cases:
Flame does NOT appear
Actions: • Check: - combustion chamber position and cleanliness;
• arrival of combustion air in the combustion chamber;
• if the heating element is working (DEALER);
• room temperature (if lower than 3°C use a relighter) and damp.
Try to light with a relighter (see page 38).
Flames appear, but AF appears on the display after Ar
Actions: • Check: (only by the Dealer)
• if the thermocouple is working (DEALER);
• start-up temperature setting in the parameters (DEALER).
• Repeat start up after having emptying the brazier.
5) Signalling: Black Out: (not a defect of the stove).
Problem: Turns off due to lack of electricity
Actions: • Check electricity connection and drops in voltage.
6) Signalling: Fault/RC: (intervenes if the thermo coupling has failed or is disconnected).
Problem: Turns off due to thermo coupling failed or disconnected
Actions: • Check connection of thermo coupling to board: check function in cold test (DEALER).
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Story at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Story in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info