INSTALLATION
AIR INTAKES
The combustion air intake must be made in the lower
part of an external wall and its section must be at least
250 sq.cm.
The intake must be closed with protection grilles.
Air intakes cannot be opened towards areas with
potentially polluted air such as tool sheds, garages or
warehouses.
Make sure that the air intakes are always free from
obstructions.
CONNECTION TO THE FLUE
This chapter has been drawn up pursuant to European
regulations EN 13384, EN 1443, EN 1856 and EN
1457. The installer must observe both these and any
other local regulations. This manual does not in any
way substitute such regulations.
The product must be connected to a flue system which
ensures that the fumes produced by combustion are
expelled in complete safety.
Before positioning the appliance, the installer must
check that the flue is suitable.
The boiler works by forced draught, therefore a smoke
extractor provides combustion air to the chamber
enabling the combustion. It is therefore necessary to
ensure a correct evacuation of the fumes by connecting
the boiler to a flue that guarantees a natural draft.
Local and national regulations must be observed when
connecting the appliance to a flue.
The flue must meet the following requirements:
It must be made with waterproof material resistant
to the fume temperature and related condensation.
It must be of sufficient mechanical resistance and
have low thermal conductivity.
It must be perfectly sealed to prevent cooling.
It must be as vertical as possible.
It must be placed at an adequate distance from
combustible or flammable materials by means of
an air gap or suitable insulation.
Old or new chimneys which do not comply with
specifications can be recovered by intubating
the chimney. Therefore, a metal flue must be
introduced inside the existing chimney together
with suitable insulating material.
The diameter of the flue pipe must not be smaller
than that of the boiler's outlet connection.
The diameter of the flue pipe must not be smaller
than that of the boiler's outlet connection.
The internal section must preferably be circular;
square or rectangular sections must have rounded
corners with a radius of at least 20 mm.
The internal section must be constant, smooth,
independent and without bottlenecks.
Smoke pipes must not pass through areas where
the installation of combustion equipment is
prohibited.
Flexible pipes are not permitted.
A “T” shaped pipe must be installed immediately
after the boiler outlet in order to carry out periodic
cleaning of any residues.
A collective flue duct cannot be used.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin LAGUNA W Up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin LAGUNA W Up in the language / languages: English as an attachment in your email.

The manual is 4.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin LAGUNA W Up

Edilkamin LAGUNA W Up Usermanual and installation guide - French, Italian - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info